Related Experiment Video
Updated: Feb 7, 2026

Accuracy in Dental Medicine, A New Way to Measure Trueness and Precision
Published on: April 29, 2014
Rifampin levels in daily practice: the accuracy of a single measurement
T J F Vanbrabant1, A C Dijkmans, J den Hartigh
1Department of Infectious Diseases, Leiden University Medical Center, Leiden, the Netherlands.
Background:
Measurement of rifampin levels is not part of routine practice. However, low levels are associated with failure of tuberculosis treatment. The clinical relevance of serum levels in daily practice is unclear. The objective was to evaluate rifampin serum concentrations and factors associated with insufficient concentrations.
Methods:
Patients with at least one rifampin concentration drawn 3 hours after intake (C3) between 2005 and 2014 were included. Data on demographic and clinical characteristics were collected, including side effects and dose adjustments. Two different criteria were used to define adequate concentrations (criterion 1: C3 a nd C 6 ≥ 3 mg/l; criterion 2: C3 or C6 ≥ 5 mg/l).
Results:
Of 63 patients, 66% and 76% had a sufficient level according to criterion 1 or 2, respectively. C3 exceeded C6 in most patients, while a late maximum was significantly associated with diabetes mellitus (p = 0.003). A dose adjustment was made in 19% of cases, more frequently in patients with insufficient levels (p = 0.02) or with ≥ 2 side effects (p = 0.03).
Conclusion:
Rifampin levels varied but were mostly adequate and a single measurement at 3 hours after intake provided the required information in most cases, indicating that full AUC0-24 measurements could be limited to specific situations.
Related Concept Videos
Uncertainty in Measurement: Accuracy and Precision
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated....
Improving Translational Accuracy
Ordinal Level of Measurement
Data measured using an ordinal scale are similar to nominal scale data, but there is one major difference. The ordinal scale data can be ordered. An example of ordinal scale data is a list of the top five national parks...
Interval Level of Measurement
Data measured using the interval scale are similar to ordinal level data because they have a definite arrangement. However, in the interval level of measurement, the differences between data values are meaningful even though the data does not have a starting point.
Temperature is measured using the interval scale. It is measurable data, and the difference between...
Nominal Level of Measurement
The data that cannot be measured but can be grouped into categories fall under the nominal level of measurement. Data that is measured using a nominal...

