Introduction:
The presence of errors in the preanalytical phase is a thoroughly studied problem. A strategy to increase their source detection might be the use of the Healthcare Failure Mode and Effects Analysis (HFMEA). The aim of this study is improving the capacity of identifying sources of error during the preanalytical period in samples provided by primary care clinics (PCC) with the use of the HFMEA as a tool in the laboratories of two tertiary hospitals.
Materials And Methods:
A HFMEA was carried out in each laboratory, by means of the creation of groups of experts with similar characteristics (doctors and nurses from PCC and laboratory, support staff, and laboratory technicians). The Risk Priority Number (RPN) was calculated.
Results:
Items with elevated RPN were presented in both centers. The highest RPN were in LAB1: "two request notes for a patient" and "the segregation of oncology urgent samples" (both with 384), while in LAB2 was "the lack of information in patients with oral glucose overload test" (RPN 576). Considering the different steps in the preanalytical phase, LAB1 paid attention in sampling, samples reception and the programming in the Laboratory Information System, while LAB2 paid attention in the request form, the appointment system, sampling procedures, transport and reception.
Conclusion:
The laboratories prioritized the problems differently. However, both centers offer solutions to these possible sources of error. We proposed improvement actions that can be resolved easily, with a low cost for the system, mainly to schedule a specific formative programme and a deep revision of the existing protocols.
More Related Videos
09:30Open Source High Content Analysis Utilizing Automated Fluorescence Lifetime Imaging Microscopy
Published on: January 18, 2017
04:05Author Spotlight: Unveiling Prognostic Indicators in Heart Failure - The Role of Phase Angle and Bioelectrical Impedance Analysis
Published on: June 30, 2023
Related Concept Videos
Tertiary Healthcare System
Hospitals-II
Nurses that work in...
Hospitals-I
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Nodal Analysis with Voltage Sources
Consider a circuit that contains four resistors and two voltage sources, as shown in Figure 1. One of these voltage sources is connected between a...
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...