Related Experiment Video
Updated: Feb 7, 2026

Preparation and Testing of Plant Seed Meal-based Wood Adhesives
Published on: March 5, 2015
Outpatient versus inpatient mixed meal tolerance and arginine stimulation testing yields comparable measures of
Sudha S Shankar1, Douglas S Lee2, Ralph H Raymond3
1Eli Lilly and Company, United States.
Standard practice to minimize variability in beta cell function (BCF) measurement is to test in inpatient (IP) settings. IP testing strains trial subjects, investigators, and budgets. Outpatient (OP) testing may be a solution although there are few reports on OP BCF testing variability. We compared variability metrics between OP and IP from a standardized mixed meal tolerance test (MMTT) and arginine stimulation test (AST) in two separate type 2 diabetes (T2DM) cohorts (OP, n = 20; IP n = 22) in test-retest design. MMTT variables included: insulin sensitivity (Si); beta cell responsivity (Φtot); and disposition index (DItot = Si* Φtot) following 470 kCal meal. AST variables included: acute insulin response to arginine (AIRarg) and during hyperglycemia (AIRargMAX).
Standard practice to minimize variability in beta cell function (BCF) measurement is to test in inpatient (IP) settings. IP testing strains trial subjects, investigators, and budgets. Outpatient (OP) testing may be a solution although there are few reports on OP BCF testing variability. We compared variability metrics between OP and IP from a standardized mixed meal tolerance test (MMTT) and arginine stimulation test (AST) in two separate type 2 diabetes (T2DM) cohorts (OP, n = 20; IP n = 22) in test-retest design. MMTT variables included: insulin sensitivity (Si); beta cell responsivity (Φtot); and disposition index (DItot = Si* Φtot) following 470 kCal meal. AST variables included: acute insulin response to arginine (AIRarg) and during hyperglycemia (AIRargMAX).
Results:
Baseline characteristics were well-matched. Between and within subject variance for each parameter across cohorts, and intraclass correlation coefficients (ICC-a measure of reproducibility) across parameters were generally comparable for OP to IP. Table summarizes the ICC results for each key parameter and cohort. [Table: see text] In conclusion, the variability (reproducibility) of BCF measures from standardized MMTT and AST is comparable between OP and IP settings. These observations have significant implications for complexity and cost of metabolic studies.
Related Concept Videos
ATP Yield
The ETC is embedded in the inner mitochondrial membrane and is comprised of four main protein complexes and an ATP synthase. NADH and FADH2 pass electrons to these complexes, which pump protons into the intermembrane space. This distribution of...
Reaction Yield
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Comparative Excretory Systems
Serum Studies: Renal Function Tests
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...

