Background:
Patient-specific instruments (PSIs) were developed to improve mechanical axis alignment for patients undergoing total knee arthroplasty (TKA) as neutral alignment (180°) is a predictor of long-term success. This study examines alignment accuracy and functional outcomes of PSI as compared with standard instruments (SIs).
Methods:
We retrospectively reviewed a consecutive series of TKA procedures using PSI. A total of 85 PSI procedures were identified, and these were compared with a matched cohort of 85 TKAs using SI. Intraoperative decision-making, estimated blood loss, efficiency, Knee Society Scores, and postoperative radiographs were evaluated.
Results:
One hundred and seventy patients with comparable patient demographics were reviewed. Eighty-one percent of the PSI procedures were within target (180 ± 3°) mechanical alignment, while the SI group had 70% of cases within the target plane ( P = .132). Mean target alignment (2.0° PSI vs 2.2° SI, P = .477) was similar between groups. Twenty-seven percent of patients in the PSI group had surgeon-directed intraoperative recuts to improve the perceived coronal alignment. The change in hematocrit was reduced in the PSI group (8.89 vs 7.21, P = .000). Procedure time and total operating room time were equivalent. Knee Society Scores did not differ between groups at 6 months or at 1 year.
Conclusion:
Patient-specific instrumentation decreased change in hematocrit, though coronal alignment and efficiency were equivalent between groups. Surgeons must evaluate cuts intraoperatively to confirm alignment. Functional outcomes are equivalent for PSI and SI groups.
Related Concept Videos
Uncertainty in Measurement: Accuracy and Precision
Improving Translational Accuracy
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...
Accuracy and Precision
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...