In Silico Screening of Metal-Organic Frameworks for Adsorption-Driven Heat Pumps and Chillers
Related Experiment Video
Updated: Feb 7, 2026

Author Spotlight: Characterizing Porous Materials for Aiding the Development of Robust Metal-Organic Frameworks with Adsorption Behavior
Published on: March 8, 2024
Máté Erdős1, Martijn F de Lange1, Freek Kapteijn2
1Engineering Thermodynamics, Process & Energy Department, Faculty of Mechanical, Maritime and Materials Engineering , Delft University of Technology , Leeghwaterstraat 39 , 2628CB Delft , The Netherlands.
Abstract:
A computational screening of 2930 experimentally synthesized metal-organic frameworks (MOFs) is carried out to find the best-performing structures for adsorption-driven cooling (AC) applications with methanol and ethanol as working fluids. The screening methodology consists of four subsequent screening steps for each adsorbate. At the end of each step, the most promising MOFs for AC application are selected for further investigation. In the first step, the structures are selected on the basis of physical properties (pore limiting diameter). In each following step, points of the adsorption isotherms of the selected structures are calculated from Monte Carlo simulations in the grand-canonical ensemble. The most promising MOFs are selected on the basis of the working capacity of the structures and the location of the adsorption step (if present), which can be related to the applicable operational conditions in AC. Because of the possibility of reversible pore condensation (first-order phase transition), the mid-density scheme is used to efficiently and accurately determine the location of the adsorption step. At the end of the screening procedure, six MOFs with high deliverable working capacities (∼0.6 mL working fluid in 1 mL structure) and diverse adsorption step locations are selected for both adsorbates from the original 2930 structures. Because the highest experimentally measured deliverable working capacity to date for MOFs with methanol is ca. 0.45 mL mL-1, the selected six structures show the potential to improve the efficiency of ACs.
Related Concept Videos
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
Refrigerators and Heat Pumps
A household refrigerator removes heat from...
ATP Driven Pumps I: An Overview
There are four main types of ATP-driven pumps - P-type, V-type, F-type, and ABC transporter. All these pumps are of varying complexities and...
Bonding in Metals
Alkali Metals
Table 1: Properties of the alkali metals