Related Experiment Video
Updated: Jan 13, 2026

Surgical Correction for Pediatric Epiblepharon and Trichiasis
Published on: July 8, 2025
Involutional entropion repair combining the modified Bick quick strip procedure with Quickert rotational sutures
1a Department of Ophthalmology , New York Presbyterian Hospital - Weill Cornell Medical College , New York , New York , USA.
Purpose:
The purpose of the study was to determine the results of involutional entropion repair by combining the modified Bick strip procedure with Quickert rotational sutures.
Methods:
A retrospective review of consecutive patients with involutional entropion who underwent repair by combined Bick and Quickert technique from January 2013 to December 2017 was performed.
Results:
A total of 43 cases of involutional entropion repair were preformed in this time period. Fourteen eyelids of 12 patients had the combined procedure. There were no failures with a median follow-up of 29 months. Mean operative time, recorded in 10 patients, was 15 ± 2.2 minutes. Complications were minimal.
Conclusions:
The combination of the modified Bick quick strip procedure and Quickert sutures requires minimal surgical dissection and provides excellent results for the treatment of involutional entropion.