Transcatheter Aortic Valve Replacement of Failed Surgically Implanted Bioprostheses: The STS/ACC Registry
E Murat Tuzcu1, Samir R Kapadia2, Sreekanth Vemulapalli3
1Cleveland Clinic, Abu Dhabi, United Arab Emirates.
Background:
Valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) has been shown to be feasible, yet the safety and efficacy in relation to native valve (NV) TAVR are not known.
Objectives:
This study sought to evaluate the safety and effectiveness of ViV TAVR for failed surgical aortic valve replacement (SAVR) by comparing it with the benchmark of NV TAVR.
Methods:
Patients who underwent ViV-TAVR (n = 1,150) were matched 1:2 (on sex, high or extreme risk, hostile chest or porcelain aorta, 5-m-walk time, and Society of Thoracic Surgeons Predicted Risk of Mortality for reoperation) to patients undergoing NV-TAVR (n = 2,259). Baseline characteristics, procedural data, and in-hospital outcomes were obtained from the Transcatheter Valve Therapy Registry. The 30-day and 1-year outcomes were obtained from linked Medicare administrative claims data.
Results:
Unadjusted analysis revealed lower 30-day mortality (2.9% vs. 4.8%; p < 0.001), stroke (1.7% vs. 3.0%; p = 0.003), and heart failure hospitalizations (2.4% vs. 4.6%; p < 0.001) in the ViV-TAVR compared with NV-TAVR group. Adjusted analysis revealed lower 30-day mortality (hazard ratio: 0.503; 95% confidence interval: 0.302 to 0.839; p = 0.008), lower 1-year mortality (hazard ratio: 0.653; 95% confidence interval: 0.505 to 0.844; p = 0.001), and hospitalization for heart failure (hazard ratio: 0.685; 95% confidence interval: 0.500 to 0.939; p = 0.019) in the ViV-TAVR group. Patients in the ViV-TAVR group had higher post-TAVR mean gradient (16 vs. 9 mm Hg; p < 0.001), but less moderate or severe aortic regurgitation (3.5% vs. 6.6%; p < 0.001). Post-TAVR gradients were highest in small SAVRs and stenotic SAVRs.
Conclusions:
Comparison with the benchmark NV-TAVR shows ViV-TAVR to be a safe and effective procedure in patients with failed SAVR who are at high risk for repeat surgery.
Related Concept Videos
Hypothesis: Accept or Fail to Reject?
There are two ways to indicate that the null hypothesis is not rejected. 'Accept' the null...
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Continuous Renal Replacement Therapy
Mitral Valve Prolapse I: Introduction
Aortic Regurgitation I: Introduction
Mitral Valve Prolapse II: Assessment and Management