The validity and reliability of DrGoniometer, a smartphone application, for measuring forearm supination
1Faculty of Health Sciences, School of Physiotherapy, Australian Catholic University, North Sydney, New South Wales, Australia.
Summary
DrGoniometer, a smartphone app, is a reliable and valid tool for measuring forearm supination in patients with forearm fractures. It offers a convenient alternative to traditional universal goniometers for clinical use.
Area of Science:
- Orthopedics and Rehabilitation Science
- Biomedical Engineering
- Clinical Measurement Validation
Background:
- Forearm supination is crucial for daily activities, commonly measured with universal goniometers.
- DrGoniometer, a smartphone application, has prior validation for other joint measurements.
Purpose of the Study:
- To assess the reliability and validity of DrGoniometer for forearm supination measurement.
- To evaluate its use in healthy individuals and those with forearm fractures.
Main Methods:
- A clinical measurement study involving 30 participants with non-surgically treated distal radius fractures and 30 healthy controls.
- Forearm supination was measured using DrGoniometer and a universal goniometer by two blinded assessors.
- Reliability was determined using Intra-class Correlation Coefficients (ICCs), standard error of measurement, and minimal detectable change. Validity was assessed using Pearson's correlation coefficient.
Main Results:
- High intra-rater reliability (ICCs 0.74-0.88) was observed for both devices in both groups.
- Inter-rater reliability was high for the fractured forearm group (0.76 and 0.72) but low for the healthy forearm group (0.34 and 0.42).
- Excellent correlation (0.94 and 0.93) was found between DrGoniometer and the universal goniometer across both groups.
Conclusions:
- DrGoniometer demonstrates good-to-excellent intra-rater and inter-rater reliability for forearm supination, particularly in fractured limbs.
- While inter-rater reliability was lower in healthy forearms, potentially due to instructions, DrGoniometer is a valid and efficient alternative tool.
- The smartphone application offers advantages in speed and digital record-keeping for forearm supination assessment.
Related Concept Videos
Reliability and Validity
14.1K
Reliability and validity are two important considerations that must be made with any type of data collection. Reliability refers to the ability to consistently produce a given result. In the context of psychological research, this would mean that any instruments or tools used to collect data do so in consistent, reproducible ways.
14.1K
Muscles that Move the Forearm
3.9K
The muscles that move the forearms can be divided into four groups: forearm flexors, forearm extensors, forearm pronators, and forearm supinators. The flexors and extensors act on the elbow joint, while the pronators and supinators act on the radioulnar joints.
Forearm Flexors
The biceps brachii, brachialis, and brachioradialis are forearm flexors. The biceps brachii is made up of two heads. Its long head originates at the supraglenoid tubercle of the scapula, whereas that of the short head is...
Forearm Flexors
The biceps brachii, brachialis, and brachioradialis are forearm flexors. The biceps brachii is made up of two heads. Its long head originates at the supraglenoid tubercle of the scapula, whereas that of the short head is...
3.9K
Muscles of the Forearm that Move the Hand and Fingers
2.7K
The muscles of the forearm that move the wrist, hand, and digits are numerous and diverse. They can be classified into two groups based on their location and function — the anterior and posterior compartment muscles.
Anterior Compartment
The anterior compartment muscles originate from the humerus. They primarily function as flexors and are also known as flexor muscles. They typically insert on the carpals, metacarpals, and phalanges. The superficial layer includes the flexor carpi...
Anterior Compartment
The anterior compartment muscles originate from the humerus. They primarily function as flexors and are also known as flexor muscles. They typically insert on the carpals, metacarpals, and phalanges. The superficial layer includes the flexor carpi...
2.7K
Distribution Reliability and Automation
519
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
519
Data Validation
2.1K
Method validation is a crucial process in analytical chemistry designed to confirm that a given method consistently produces reliable and high-quality results. This process is essential when a method is applied to different sample matrices or when procedural modifications are made, ensuring that the results meet acceptable standards across various applications.
Key parameters for method validation include:
Key parameters for method validation include:
2.1K
Data Validation
6.8K
Data validation is an essential part of a comprehensive assessment. Validation is confirming or verifying and opening the door to gathering more assessment data as it clarifies vague or unclear data. The process of checking and verifying the collected information is called data validation. The primary purpose of data validation is to ensure data is as free from error, bias, and misinterpretation as possible.
Nursing assessment guides are generally based on holistic models rather than medical...
Nursing assessment guides are generally based on holistic models rather than medical...
6.8K