Related Experiment Video
Updated: Feb 7, 2026

Optic Nerve Sheath Point of Care Ultrasound: Image Acquisition
Published on: August 18, 2023
Multislice computed tomographic measurements of optic nerve sheath diameter in brain injury patients
Murat Özsaraç1, Fatih Düzgün, Yalçın Gölcük
1Department of Emergency Medicine, Celal Bayar University Faculty of Medicine, Manisa-Turkey. mozsarac@msn.com.
Background:
Currently, the measurement of optic nerve sheath diameter (ONSD) has been offered as a possible indicator of intracranial pressure (ICP). Increased ICP is observed during intracranial injury. The objective of this study was to evaluate the relationship between increased ONSD and positive intracranial findings from multislice computed tomography (CT) of the brain.
Methods:
In total, CT scans of 161 patients were retrospectively reviewed. The image that showed the largest ONSD was magnified five times.
Results:
The CT scan revealed intracranial lesions in 54 patients and no intracranial lesions in 107 patients. A significant relationship was observed between positive CT findings and increased ONSD: 5.60±0.75 mm vs. 5.35±0.75 mm (p=0.038). The area under the receiver operating characteristic curve was 0.600 (95% confidence interval, 0.508-0.692; p<0.039). A cut-off value of ≥5.0 mm had a sensitivity and specificity of 80% and 36%, respectively.
Conclusion:
This study demonstrated a significant yet poor relationship between intracranial injury and increased ONSD from the multislice CT scan. Severe structural changes in the brain and trauma that causes bleeding have only limited effects on the extension of the optic nerve.
Related Concept Videos
Design Example: Calculating Safe Diameter for Wind-Exposed Disc
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Design Example: Traverse Angle Computations
Area Computation by the Alternative Coordinate Method
Imaging Studies III: Computed Tomography
Measures of Central Tendency