Related Experiment Video
Updated: Feb 7, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
The Relationship of Multiplanar Distal and Uniplanar Proximal Interlocking Screws to Neurovascular Structures with
Garrett Steinmetz1, Jonathan Tobey, Spencer Skinner
1Department of Orthopedic Surgery, University of Oklahoma, Oklahoma City, OK.
Objective:
To determine the proximity of neurovascular structures to multiplanar distal interlocking screws and proximal interlocking devices for an antegrade inserted humeral nail.
Methods:
Humeral nails (Depuy Synthes Humeral Nail-EX, Paoli, PA) were inserted into 10 matched cadavers with 3 distal interlocking trajectories: anterior to posterior (A-P), anterolateral to posteromedial, and anteromedial to posterolateral (AM-PL). The distance of the screw path and screw head to the radial, lateral antebrachial cutaneous nerve (LACN), and median nerves and the brachial artery was measured. Proximally, the distance of spiral blades and/or interlocking screws to the axillary nerve was measured.
Results:
The median distance of the screw path/screw head inserted (A-P) to the LACN was 0 mm/0 mm in the left arm and 3.5 mm/1.6 mm in the right arm. The median distance of the screw path/screw head inserted AM-PL to the median nerve was 7.08 mm/0 mm in the left arm and 0 mm/0.12 mm in the right arm. The median distance of the screw path/screw head inserted AM-PL to the brachial artery was 4.05 mm/3.83 mm in the left arm and 2.19 mm/2.84 mm in the right arm. The humeral head was radiographically divided into 3 zones. The average distances of the axillary nerve to interlocking devices placed into zone 2 and zone 3 of the humeral head are 14.65 mm and 1.07 mm, respectively.
Conclusions:
When using the DePuy Synthes Humeral Nail-EX, AM-PL screws may risk the median nerve and brachial artery; thus, this trajectory is not recommended. The LACN may be at risk with A-P and to a lesser degree, anterolateral to posteromedial screws. Proximally, interlocking devices in zone 3 of the humeral head may risk the axillary nerve.
More Related Videos
10:36Vascularized Composite Hand Allograft Procurement and Preparation for Distal and Proximal Forearm Allotransplantation: A Stepwise Approach
Published on: May 23, 2025
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016
Related Concept Videos
Accessory Structures of the Skin: Nails
The main components of a nail include the following.
Nail Plate: The nail plate is the visible portion of the nail that extends beyond the fingertips or toes. It is a hard, translucent...
Relationship Formation
Structure-Activity Relationships and Drug Design
SAR studies the intricate relationship between a drug's chemical structure and biological activity. It focuses on understanding how modifications to a drug's structure can influence...
Local Anesthetics: Chemistry and Structure-Activity Relationship
Cholinergic Antagonists: Chemistry and Structure-Activity Relationship
Adrenergic Agonists: Chemistry and Structure-Activity Relationship
Aromatic ring substitutions: Substituting the aromatic ring with –OH groups at positions 3 and 4 yields catecholamines (e.g., epinephrine), which have a high affinity for adrenoceptors. Hydrogen bonding between –OH groups and receptors enhances adrenergic activity.
Separation of...