Related Experiment Video
Updated: Feb 7, 2026

Determination of Inorganic Arsenic in a Wide Range of Food Matrices using Hydride Generation - Atomic Absorption Spectrometry.
Published on: September 1, 2017
Determination of arsenic in agricultural soil samples using High-resolution continuum source graphite furnace atomic
Mauana Schneider1, Heloisa R Cadorim1, Bernhard Welz2
1Departamento de Química, Universidade Federal de Santa Catarina, 88040-900 Florianópolis, SC, Brazil.
Abstract:
Soils around coal-fired thermal power plants based on coal combustion can present high concentrations of arsenic. This fact has a direct effect on the food chain. Arsenic can be absorbed by plants and vegetables through the soil, which will then serve as food for different animals, spreading the contamination. A method has been developed using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS) for direct determination of arsenic in solid soil samples. Different chemical modifiers were tested to suppress the matrix effects observed. Among them, the modifier that showed the best results was the Zr, used as a permanent modifier. The optimized pyrolysis and atomization temperatures were 1000 °C and 2200 °C, respectively. A calibration curve was established using aqueous standard solutions which was linear up to 16 ng of arsenic. The characteristic mass and limit of detection were 22 pg and 73 pg As, respectively. The accuracy of the method was verified using two certified reference materials and comparison with results obtained for samples after microwave-assisted digestion. Eleven soil samples were collected around the power plant Complex Jorge Lacerda-Tractebel Suezin, in the south of Santa Catarina, Brazil. The concentration of As ranged from 3.4 mg kg-1 to 9.7 mg kg-1, which is within the limits allowed by Brazilian legislation.
Related Concept Videos
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Network Covalent Solids
To break or to melt a covalent network solid, covalent bonds must be broken. Because covalent bonds are relatively strong, covalent network solids are typically...
Atomic Absorption Spectroscopy: Atomization Methods
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
The Soil Ecosystem
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...

