Related Experiment Video
Updated: Feb 7, 2026

Technical Detail for Robot Assisted Pancreaticoduodenectomy
Published on: September 28, 2019
Technical note: Infusion, sampling, and vacuum-assisted collection devices for use in ruminally cannulated calves
T T Yohe1, H Schramm2, C L M Parsons1
1Dairy Science Department, Blacksburg 24061.
Abstract:
Calves can be ruminally cannulated at young ages, but equipment size limitations preclude use of an infusion and sampling device in these small animals. Likewise, a procedure to easily evacuate rumen contents in young calves has not been described. Overcoming these technical complications related to assessment of ruminal passage kinetics, nutrient digestion, and volatile fatty acid absorption would aid in future studies advancing our knowledge of dairy calf nutrition. The first objective was to design and fabricate 2 devices (one device for infusion and sampling, and another for vacuum-assisted collection) suitable for use in young ruminally cannulated dairy calves. The second objective was to test the utility of these tools when performing procedures commonly used in ruminant nutrition research. A single weaned 62-d-old ruminally cannulated calf was used to evaluate the ability to infuse a solution of LiCoEDTA and sample rumen contents through the cannula cap over a period of 2 h to assess the rumen liquid passage rate (procedure 1). The device was capable of infusing the LiCoEDTA and sampling the rumen fluid, as evidenced by the presence of elevated Co concentrations in the sampled rumen fluid. Using the fluid samples obtained, liquid passage rate within the calf was estimated to be 40.2% of ruminal fluid/h. The second procedure tested the vacuum-assisted collection device and consisted of evacuating and weighing the rumen contents, which is considered a key preparatory step in washed reticulorumen technique experiments that aim to measure nutrient absorption. In agreement with existing literature, evacuated rumen contents represented approximately 4% of the calf's body weight. In conclusion, custom-built devices for infusion, sampling, and vacuum-assisted collection were efficacious when tested in a 62-d-old ruminally cannulated calf fed a diet of 100% texturized starter (18% crude protein, as-fed). Fellow scientists may employ and further modify these techniques to suit their needs when assessing passage kinetics, nutrient digestion, and volatile fatty acid absorption in calves.
More Related Videos
05:54Stereo-Electro-Encephalo-Graphy SEEG With Robotic Assistance in the Presurgical Evaluation of Medical Refractory Epilepsy: A Technical Note
Published on: June 13, 2016
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
Related Concept Videos
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
Data Collection II
Data Collection I
Non-ohmic Devices
Consider a simple circuit consisting of a battery, a diode, and a resistor. A...
Mnemonic Devices
Acronyms
Acronyms are created by using the initial letters of a series of words to form a new word or phrase. This approach condenses complex information into a single, memorable entity. For example,...