Related Experiment Video
Updated: Feb 7, 2026

Generation of a Three-dimensional Full Thickness Skin Equivalent and Automated Wounding
Published on: February 26, 2015
Different immunoreactivity of monomers and dimers makes automated free light chains assays not equivalent
Laura Caponi1, Elona Koni1, Nadia Romiti1
1Department of Translational Research and New Technologies in Medicine, University of Pisa, Pisa, Italy.
Abstract:
Background The automated immunochemical serum free light chains (FLC) assays, Freelite (a polyclonal antiserum) and N Latex FLC (a mixture of monoclonal antibodies), are not interchangeable, as they may provide different results on a same sample. This study was aimed to establish if the calibrators contain FLC oligomers, and if different reactivity against monomers and dimers contributes to the discrepancy. Methods Gel filtration chromatography fractions of the calibrators were subjected to a Western blot (WB) and analyzed by each reagent. The procedure was repeated after pretreating the N Latex FLC calibrator with the reducing agent dithiothreitol (DTT). Results Both calibrators contain FLC dimers and monomers. Both reagents detect (with different sensitivity) FLC kappa monomers and dimers; instead, Freelite detects only FLC lambda dimers, while N Latex FLC detects only FLC monomers. After DTT treatment, only the N Latex lambda still detects FLC with reduced protein thiols, while the reactivity of all other reagents is abolished. Conclusions Due to their different reactivity against FLC monomers and oligomers, the Freelite and N Latex FLC are calibrated against different components of their own calibrators, making the two reagents not equivalent. The redox status of FLC determines the immunoreactivity not only of FLC dimers, but also of the monomers.
More Related Videos
10:30A High-throughput-compatible FRET-based Platform for Identification and Characterization of Botulinum Neurotoxin Light Chain Modulators
Published on: December 27, 2013
06:49Atom Transfer Radical Polymerization of Functionalized Vinyl Monomers Using Perylene as a Visible Light Photocatalyst
Published on: April 22, 2016
Related Concept Videos
Equivalent Capacitance
The following strategies are adopted to calculate...
Equivalent Capacitance
Pharmaceutical Equivalents
Thévenin Equivalent Circuits
Principle of Equivalence
Equivalent Couples
Two couples are considered to be equivalent if they produce the same rotational effect on a rigid body. In other words, the two couples have the same magnitude and act in the same direction, causing the same angular displacement or acceleration in the body.
For instance, consider two couples lying in the plane of the page, with one having a pair of equal...