Related Experiment Video
Updated: Feb 7, 2026

Diffusion Tensor Magnetic Resonance Imaging in Chronic Spinal Cord Compression
Published on: May 7, 2019
Anatomical Study of Percutaneous Trigeminal Compressive Balloon Positioning on Merged 3-D Rotational X-Ray and
Stephen Sandwell1, Simone Montoya2, James E Towner1
1Department of Neurological Surgery, University of Rochester Medical Center, Rochester, New York, USA.
Background:
Percutaneous trigeminal rhizotomy or balloon compression for trigeminal neuralgia carries a potential risk for the brainstem, the carotid artery, and the basilar artery.
Objective:
To detail the relation of critical neural and vascular structures to expanded balloons used for percutaneous compression of the trigeminal ganglion.
Method:
A retrospective analysis of preprocedural magnetic resonance imaging (MRI) and procedural X-ray-based imaging for 9 patients detailed balloon proximity to the brainstem, carotid artery, and basilar artery.
Results:
Balloons extended 10.96 ± 5.54 mm (mean ± SD) posterior to the clival line. The average distance from the balloon to the brainstem was 6.89 mm, and that to the basilar artery was 12.12 mm (range: 0-18.2). The medial edge of the balloon was an average distance of 1.39 mm from the baseline position of the carotid lumen.
Conclusion:
Preprocedural MRI, merged with 3-D rotational angiography suite imaging, detailed the proximity of the balloon to critical neural and vascular structures. Our study found that the standard technique for percutaneous trigeminal compression, with balloon placement at an average depth of 10.96 mm posterior to the clival line, on average, provided an additional 6.89 mm of space before the brainstem would have been encountered, demonstrating safe positioning.
Related Concept Videos
Imaging Studies IV: Magnetic Resonance Imaging
Anatomical Positions
The body is upright, facing forward, and standing erect.
The feet are parallel and flat on the floor.
The arms are hanging by the...
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
X-ray Imaging
Atomic Nuclei: Magnetic Resonance