Development of hybrid extreme learning machine based chemo-metrics for precise quantitative analysis of LIBS spectra
Taoreed O Owolabi1, Mohammed A Gondal1
1Laser Research Group, Physics Department, Center of Excellence in Nanotechnology, King Fahd University of Petroleum & Minerals, Box 5047, Dhahran, 31261, Saudi Arabia.
Abstract:
Laser induced breakdown spectroscopy (LIBS) is a versatile spectroscopic technique that requires little or no sample preparation and capable of simultaneous elemental sample analysis. Quantitative analysis of its spectra has been a major challenge due to self-absorption of the emitted radiation during plasma cooling and inadequate description of non-linear complex interactions taking place in the laser induced plasma. This work presents a novel chemo-metric tool, extreme learning machine (ELM) and its hybrid HHELM (homogenously hybridized ELM), for the first time in modeling the complex interactions of laser induced plasma and quantification of LIBS spectra. Internal reference preprocessing (IRP) method is also proposed as a novel method of enhancing the performance of ELM based chemo-metrics. Since the proposed chemo-metrics (ELM and HHELM) determine their input weights as well as their hidden biases in a random manner, ELM and HHELM are respectively hybridized with gravitational search algorithm (GSA) for optimization of the number of hidden neurons. Effect of IRP, obtained by normalizing the emission spectra intensities with the emission intensity that has highest upper level excitation energy and lowest transition probability, on the performance of the proposed GSA-ELM and GSA-HHELM chemo-metrics is investigated. The proposed models are implemented using spectra of seven bronze standard samples. Chemo-metrics with IRP (GSA-ELM-IRP and GSA-HHELM-IRP) show better generalization performance than those without IRP (GSA-ELM-WIRP and GSA-HHELM-WIRP) while GSA-HHELM based chemo-metrics perform better than their counterparts. The outstanding performance demonstrated by the proposed chemo-metrics and their self-absorption correction ability would definitely widen the applicability of LIBS and improve its precision for the quantitative analysis.
Related Concept Videos
pre-mRNA Processing
Once about 20-40 ribonucleotides have been joined together by RNA polymerase, a group of enzymes adds a “cap” to the 5’ end of the growing transcript. In this process, a 5’ phosphate is replaced by modified guanosine that has a methyl group attached to it (7-Methyl...
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Pre-mRNA Processing: Modification of pre-mRNA Ends
Once about 20-40 ribonucleotides have been joined together by RNA polymerase, a group of enzymes adds a cap to the 5' end of the growing transcript. In this process, a 5' phosphate is replaced by modified guanosine that has a methyl group attached (7-methyl guanosine). This 5' cap helps...
Chromatin Structure Regulates pre-mRNA Processing
The chromatin structure, especially...
Pre-mRNA Processing: RNA Splicing
Emission Spectra