Related Experiment Video
Updated: Feb 7, 2026

A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
A novel technique to intubate patients without reliable pulse oximetry
Tony Zitek1, Ross P Berkeley1, Ryan Hodnick2
1University of Nevada, Las Vegas School of Medicine, Department of Emergency Medicine, 901 Rancho Lane, Las Vegas, NV 89106, United States of America; University Medical Center of Southern Nevada, Department of Emergency Medicine, 1800 W Charleston Blvd, Las Vegas, NV 89102, United States of America.
Abstract:
Although advances have been made in the approach to airway management, intubating critically ill patients in the Emergency Department (ED) can still be perilous. In some cases, poor peripheral perfusion may preclude obtaining a consistent or reliable pulse oximetry waveform, and the intubator will not accurately know when the patient begins to desaturate. We describe a case of a patient requiring intubation in whom we were unable to obtain a consistent pulse oximetry waveform. We utilized a novel technique in which a Biphasic Cuirass Ventilation (BCV) device was applied to maintain oxygenation and ventilation during the performance of rapid sequence intubation (RSI). This technique has the potential to improve the safety of RSI, especially in the critically ill patient.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Voltammetric Techniques: Pulse Voltammetry
Reliability and Validity
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...