Related Experiment Video
Updated: Feb 7, 2026

Improved UPLC-UV Method for the Quantification of Vitamin C in Lettuce Varieties Lactuca sativa L. and Crop Wild Relatives Lactuca spp.
Published on: June 30, 2020
[Improved Reliability of Vitamin Analysis in Foodstuffs Using a Microbiological Assay Method: Construction of
Ippei Suzuki1, Jun Takebayashi1, Keizo Umegaki1
1National Institute of Health and Nutrition, National Institute of Biomedical Innovation, Health and Nutrition.
Abstract:
Vitamins are essential nutrients for human beings. Therefore, accurate determination of vitamin levels in foodstuffs is vital to confirm the proper intake of vitamins. The microbiological assay (MBA), which is used worldwide for the determination of several vitamins in foodstuffs, is very sensitive and can determine ng/mL levels of vitamins. However, the correlation between vitamin concentrations in a sample solution and the plotted growth is usually shown as a sigmoid curve. Therefore, a calibration curve derived from a linear regression may lead to error. In this study, we evaluated the effects of various models (linear, quadratic, and cubic regression models and a four-parameter logistic model (4PLM)) for calibration curve construction on the determination of vitamin B6 in infant formula. Among the four models, the calibration curve constructed with 4PLM was the most reliable for vitamin B6 determination. Moreover, the calibration curve based on 4PLM showed robustness for extrapolation; even if the vitamin concentration in the sample solution deviated from the range of the standard solution, a reasonable result could be obtained. Similarly, the 4PLM calibration curve was the most reliable for niacin determination. We conclude that 4PLM should be used for calibration curve construction to improve the reliability of vitamin determination in foodstuffs using MBA.
More Related Videos
07:34Author Spotlight: Advancing Prostate Cancer Research Through Improved Tissue Sampling and Biobanking
Published on: November 17, 2023
09:52Combinational Treatment of Trichostatin A and Vitamin C Improves the Efficiency of Cloning Mice by Somatic Cell Nuclear Transfer
Published on: April 26, 2018
Related Concept Videos
Calibration Curves: Correlation Coefficient
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Reliability and Validity
Sieve Analysis and Grading Curves
Precipitation Titration Curve: Analysis
Bending of Curved Members - Strain Analysis
The important part of bending analysis for such a member...