Related Experiment Video
Updated: Feb 7, 2026

High Resolution 3D Imaging of Ex-Vivo Biological Samples by Micro CT
Published on: June 21, 2011
Ultra-High Resolution Photon-Counting Detector CT Reconstruction using Spectral Prior Image Constrained
Kishore Rajendran1, Shengzhen Tao1, Dilbar Abdurakhimova1
1Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, USA 55905.
Abstract:
Photon-counting detector based CT (PCD-CT) enables dose efficient high resolution imaging, in addition to providing multi-energy information. This allows better delineation of anatomical structures crucial for several clinical applications ranging from temporal bone imaging to pulmonary nodule visualization. Due to the smaller detector pixel sizes required for high resolution imaging, the PCD-CT images suffer from higher noise levels. The image quality is further degraded in narrow energy bins as a consequence of low photon counts. This limits the potential benefits that high-resolution PCD-CT could offer. Conventional reconstruction techniques such as the filtered back projection (FBP) have poor performance when reconstructing noisy CT projection data. To enable low noise multi-energy reconstructions, we employed a spectral prior image constrained compressed sensing (SPICCS) framework that exploits the spatio-spectral redundancy in the multi-energy acquisitions. We demonstrated noise reduction in narrow energy bins without losing energy-specific attenuation information and spatial resolution. We scanned an anthropomorphic head phantom, and a euthanized pig using our whole-body prototype PCD-CT system in the ultra-high resolution mode at 120kV. Image reconstructions were performed using SPICCS and compared with conventional FBP. Noise reduction of 18 to 46% was noticed in narrow energy bins corresponding to 25 - 65 keV and 65 - 12 keV, while the mean CT number was preserved. Spatial resolution measurement showed similar modulation transfer function (MTF) values between FBP and SPICCS, demonstrating preservation of spatial resolution.
More Related Videos
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...

