A new assay to evaluate microvesicle plasmin generation capacity: validation in disease with fibrinolysis imbalance
Sylvie Cointe1,2, Karim Harti Souab3, Tarik Bouriche4
1Aix-Marseille Université, C2VN, UMR-1263, INSERM, INRA 1260, UFR de Pharmacie, Marseille, France.
Abstract:
Among extracellular vesicles, leukocyte-derived microvesicles (LMVs) have emerged as complex vesicular structures. Primarily identified as procoagulant entities, they were more recently ascribed to plasmin generation capacity (MV-PGC). The objectives of this work were (1) to develop a new hybrid bio-assay combining the specific isolation of LMVs and measurement of their PGC, and compare its performance to the original method based on centrifugation, (2) to validate MV-PGC in septic shock, combining increased levels of LMVs and fibrinolytic imbalance. Using plasma sample spiked with LMVs featuring different levels of PGC, we demonstrated that CD15-beads specifically extracted LMVs. The MV dependency of the test was demonstrated using electron microscopy, high speed centrifugation, nanofiltration and detergent-mediated solubilization and the MV-PGC specificity using plasmin-specific inhibitors, or antibodies blocking elastase or uPA. Thanks to a reaction booster (ε-ACA), we showed that the assay was more sensitive and reproducible than the original method. Moreover, it exhibited a good repeatability, inter-operator and inter-experiment reproducibility. The new immunomagnetic bio-assay was further validated in patients with septic shock. As a result, we showed that MV-PGC values were significantly lower in septic shock patients who died compared to patients who survived, both at inclusion and 24 h later (1.4 [0.8-3.0] vs 3.1 [1.7-18] A405 × 10-3/min, p = 0.02; 1.4 [1-1.6] vs 5.2 [2.2-16] A405 × 10-3/min, p = 0.004). Interestingly, combining both MV-PGC and PAI-1 in a ratio significantly improved the predictive value of PAI-1. This strategy, a hybrid capture bioassay to specifically measure LMV-PGC using for the first time, opens new perspectives for measuring subcellular fibrinolytic potential in clinical settings with fibrinolytic imbalance.
Insights
This study developed a new assay to measure leukocyte-derived microvesicles
Area of Science:
- Extracellular vesicles research
- Hemostasis and thrombosis
- Septic shock pathophysiology
Background:
- Leukocyte-derived microvesicles (LMVs) are implicated in hemostasis.
- LMVs possess plasmin generation capacity (MV-PGC), influencing fibrinolysis.
- Septic shock involves LMVs and fibrinolytic imbalance.
Purpose of the Study:
- Develop a novel hybrid bio-assay for specific LMV isolation and MV-PGC measurement.
- Compare the new assay to the traditional centrifugation method.
- Validate MV-PGC in septic shock patients to assess its prognostic value.
Main Methods:
- Developed a hybrid immunomagnetic assay using CD15-beads for LMV isolation.
- Confirmed MV specificity through electron microscopy, nanofiltration, and detergent treatment.
- Validated MV-PGC measurement in septic shock patients and assessed its correlation with outcomes.
- Investigated the combined predictive value of MV-PGC and PAI-1.
Main Results:
- The CD15-beads specifically isolated LMVs, demonstrating MV dependency and specificity.
- The new assay, enhanced with ε-ACA, showed improved sensitivity, reproducibility, and repeatability.
- Lower MV-PGC values were observed in non-survivors of septic shock compared to survivors.
- Combining MV-PGC with PAI-1 significantly improved the predictive value for septic shock outcomes.
Conclusions:
- A novel, sensitive, and reproducible hybrid bio-assay for LMV-PGC measurement was developed.
- MV-PGC is a potential biomarker for predicting outcomes in septic shock.
- This assay offers new perspectives for assessing fibrinolytic potential in clinical settings.
More Related Videos
Related Concept Videos
Lung Capacity
Clot Retraction and Fibrinolysis
Homeostatic Imbalance
However, sometimes these feedback loops fail,...
Reliability and Validity
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Homeostatic Imbalances in Body Temperature