[Error Correction of Spectral Calibration for Hyper-Spectral Atmosphere CO2 Monitoring Instrument]
Abstract:
The detection of hyper-spectral atmosphere CO2 needs remote sensor to be characterized and calibrated precisely while spectral calibration is the most basic work. The high uncertainty of wavelength calibration coefficient is a big problem as to the traditional laboratory calibration methods. In order to solve this problem, the research of error correction of spectral calibration based on gas absorption principle is carried out. The method is in accordance with the using conditions of instrument and it improves the practicability of the calibration coefficient. First, theoretical spectrum and error components are simulated by using radiative transfer. Then, the experiment of atmosphere CO2 absorption spectrum measurement is performed based on the atmosphere environmental simulation calibration house. Last, spectral error is corrected and optimized with LM algorithm. The result of spectral calibration of error correction shows that the mean value of spectral error deviation decreases from 0.03 cm-1 before correction to 0.008 cm-1 after correction, and systematic and mutable errors are removed. The spectral calibration precision on the ground is improved significantly, which lays the foundation for the subsequent greenhouse gas retrieval.
More Related Videos
11:37RGB and Spectral Root Imaging for Plant Phenotyping and Physiological Research: Experimental Setup and Imaging Protocols
Published on: August 8, 2017
14:26In vivo Quantification of G Protein Coupled Receptor Interactions using Spectrally Resolved Two-photon Microscopy
Published on: January 19, 2011
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
NMR Spectrometers: Resolution and Error Correction
Errors occurring during blood pressure monitoring
Several factors...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Distance Corrections
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...