Related Experiment Video
Updated: Feb 7, 2026

A Fabrication and Measurement Method for a Flexible Ferroelectric Element Based on Van Der Waals Heteroepitaxy
Published on: April 8, 2018
Controllable conductive readout in self-assembled, topologically confined ferroelectric domain walls
Ji Ma1, Jing Ma1, Qinghua Zhang2
1State Key Lab of New Ceramics and Fine Processing, School of Materials Science and Engineering, Tsinghua University, Beijing, China.
Abstract:
Charged domain walls in ferroelectrics exhibit a quasi-two-dimensional conduction path coupled to the surrounding polarization. They have been proposed for use as non-volatile memory with non-destructive operation and ultralow energy consumption. Yet the evolution of domain walls during polarization switching makes it challenging to control their location and conductance precisely, a prerequisite for controlled read-write schemes and for integration in scalable memory devices. Here, we explore and reversibly switch the polarization of square BiFeO3 nanoislands in a self-assembled array. Each island confines cross-shaped, charged domain walls in a centre-type domain. Electrostatic and geometric boundary conditions induce two stable domain configurations: centre-convergent and centre-divergent. We switch the polarization deterministically back and forth between these two states, which alters the domain wall conductance by three orders of magnitude, while the position of the domain wall remains static because of its confinement within the BiFeO3 islands.
Related Concept Videos
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the...
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Conservation of Protein Domains Over Different Proteins
A limited set of protein domains often duplicate and recombine during evolution. These domains can be organized in different combinations to...