[Endoprosthetic wear analysis using virtual CAD-based radiographs]

M Haversath1, S Klebingat2,

  • 1Klinik für Orthopädie und Unfallchirurgie, Universitätsmedizin Essen, Hufelandstraße 55, 45147, Essen, Deutschland.

Der Orthopade
|July 25, 2018
PubMed
Summary

A new computer-aided detection (CAD) method accurately measures polyethylene wear in hip replacements. This validated technique aids in evaluating advanced materials like vitamin E-blended polyethylene, improving implant longevity.

Related Concept Videos

Virtual Work01:20

Virtual Work

The principle of virtual work states that if a body is in static and dynamic equilibrium, then the sum of all the virtual work done by all external forces and couple moments for any given virtual displacement must be zero.
In static equilibrium, a body can experience an imaginary or virtual movement, such as displacement or rotation. The virtual work done by a force is equal to the dot product of force and virtual displacement in the direction of the force. When it comes to virtually rotating a...
1.4K
Principle of Virtual Work: Problem Solving01:13

Principle of Virtual Work: Problem Solving

The principle of virtual work is an essential concept in the field of mechanics and engineering. This is used to solve problems related to the equilibrium of a structure or system. It is based on the assumption that if a system is in equilibrium, the work done by all the forces during a virtual displacement is zero. This principle is applied by considering virtual displacements of the system and the corresponding work done by internal and external forces.
To apply the principle of virtual work,...
1.7K
Virtual Work for a System of Connected Rigid Bodies01:06

Virtual Work for a System of Connected Rigid Bodies

Virtual work is a powerful method used to solve problems involving several connected rigid bodies. When the system is in equilibrium, virtual work is zero. This allows the calculation of the resulting forces when a system undergoes a virtual displacement. When attempting to analyze such a system, first, use a free-body diagram, where an independent coordinate represents the configuration of the links, and mark its deflected position resulting from the positive virtual displacement.
Next,...
761
Classification of Titrimetric Analysis Based on Reaction Types01:01

Classification of Titrimetric Analysis Based on Reaction Types

Titrimetric analysis in solution chemistry involves measuring the volume of solutions and is often called volumetric analysis. The standard solution of known concentration in the burette is called the titrant, whereas the solution of unknown concentration in the flask is called the analyte, or titrand. Titrimetric analyses can be classified into four types based on the reactions between the titrant and analyte.
Titrations between an acid and a base lead to neutralization reactions that form...
1.8K
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy01:26

Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy

This lesson explores three gastrointestinal imaging techniques: radionuclide testing, colonic transit studies, and virtual colonoscopy.
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
431
Qualitative Analysis03:46

Qualitative Analysis

For solutions containing mixtures of different cations, the identity of each cation can be determined by qualitative analysis. This technique involves a series of selective precipitations with different chemical reagents, each reaction producing a characteristic precipitate for a specific group of cations. Metal ions within a group are further separated by varying the pH, heating the mixture to redissolve a precipitate, or adding other reagents to form complex ions.
For instance, group IV...
24.5K