Related Experiment Video
Updated: Feb 7, 2026

Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Purification of lipase from Aspergillus fumigatus using Octyl Sepharose column chromatography and its
Akshita Mehta1, Chetna Grover1, Reena Gupta1
1Department of Biotechnology, Himachal Pradesh University, Summerhill, Shimla, Himachal Pradesh, India.
Abstract:
Lipases are ubiquitous biological macromolecules which have many industrial and environmental applications. The purpose of this study was to purify lipase from Aspergillus fumigatus by using Octyl Sepharose column chromatography. The enzyme was purified by ammonium sulfate precipitation and hydrophobic interaction chromatography which resulted in sevenfold purification. The molecular weight of protein using Native-PAGE was found to be 70 kDa. The apparent molecular weight by SDS-PAGE was found to be 35 kDa which indicated that the enzyme was homodimer. The optimum temperature and pH for activity of the enzyme was found to be 40 °C and 9.0, respectively. The kinetic parameters Vmax and Km of the purified lipase were 10.42 µmol min-1 mg-1 and 9.89 mM, respectively. Detergents Tween-20 and Triton X-100 inhibited enzyme activity. However, there was minimal loss of enzyme activity with SDS and Tween-80. All metal ions inhibited the enzyme activity. Among solvents, maximum loss (65%) in the enzyme activity was in hexane.
More Related Videos
15:01Confocal Laser Scanning Microscopy-Based Quantitative Analysis of Aspergillus fumigatus Conidia Distribution in Whole-Mount Optically Cleared Mouse Lung
Published on: September 18, 2021
09:43Measuring Phagocytosis of Aspergillus fumigatus Conidia by Human Leukocytes using Flow Cytometry
Published on: December 7, 2019
Related Concept Videos
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Principles Of Column Chromatography
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Muscles of the Vertebral Column
Superficial Layer:
The superficial layer consists primarily of the splenius muscles, which include the splenius capitis and splenius cervicis. These muscles are mainly responsible for the head and cervical spine movements, including extension, rotation, and lateral bending. The splenius capitis...