Label-free fluorescent and electrochemical biosensors based on defective G-quadruplexes
Jing Zhang1, Liang-Liang Wang2, Mei-Feng Hou1
1College of Life Sciences, Fujian Agriculture and Forestry University, Fuzhou, Fujian Province 350002, PR China.
Abstract:
Abnormal levels of guanine closely associated with plenty of diseases are usually used as a biomarker for clinical diagnosis. In order to detect guanine and its derivatives accurately, in this paper, a defective G-quadruplex (DGQ) containing a G-vacancy at one of its G-quartet layers, and two kinds of G-quadruplex specific indicators including thioflavine T (ThT) and hemin were used for constructing a fluorescent and an electrochemical biosensor, respectively. In brief, a G-rich DNA probe is designed to form either hairpin or DGQ structure. In the absence of guanine, G-rich probes prefer to maintain hairpin structure and nearly have no interaction with ThT or hemin, leading to almost negligible signals. Upon addition of guanine, the G-rich probe fold into DGQ structure and then the G-vacancy in it is filled up immediately by guanine via Hoogsteen hydrogen bonds, resulting canonical G-quadruplex formation. Accordingly, ThT or hemin can selectively combine with G-quadruplex, giving rise to distinct fluorescent or current signal changes for label-free detection of guanine. Benefiting from the perfect discriminative ability of guanine towards DGQ and ThT/hemin against standard G-quadruplex, the fluorescent and electrochemical biosensors present better sensitivity and selectivity for guanine detection with the limit of detection (LOD) as low as 18.26 and 0.36 nM, respectively. Successful attempts were also made in applying the proposed electrochemical biosensor to detect guanine in drugs and urine, obtaining satisfactory recovery rates of 99~104% and 96~106%, respectively.
Related Concept Videos
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Lumber Defects
Shakes are minor fractures that run along or across the wood's annual rings, while wane is...
Interfacial Electrochemical Methods: Overview
Electrochemical Gradient and Channel Proteins: An Overview
The electrical gradient: The electrical gradient across cell membranes refers to the difference in electric charge between the inside and outside of a cell. This difference drives the movement of ions towards or away from the cells. For instance, if the inside of the cell is more negatively charged relative to...
Labeling Emotion
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...