What a difference a clip makes! Analysis of boost volume definition in radiation therapy for conservative breast
Thiago Brasileiro de Freitas1, Kennya Medeiros Lopes de Barros Lima1, Heloísa de Andrade Carvalho2
1Department of Radiology and Oncology, Division of Radiation Oncology, Faculdade de Medicina da Universidade de São Paulo, Sao Paulo, Brazil.
Purpose/Objective(S):
To evaluate the role of surgical clips placement in the definition of boost treatment volume.
Materials/Methods:
Clinical Target Volumes (CTV) were defined as: CTV Breast, CTV Quadrant (based on physical exam and pre-surgical images), CTV Boost, defined by clip plus margin (1 cm for 2 or more clips and 2 cm for 1 clip only) plus radiological changes, CTV NT (normal tissue), defined by CTV Quadrant minus CTV Boost and CTV MISS (CTV that would be outside the treatment volume), defined by CTV Boost minus CTV Quadrant.
Results:
A total of 247 patients were included. Upper lateral quadrant was the most common clinical location (47.3%). The median number of clips used was three. The mean volumes were: CTV Breast:982.52 cc, CTV Boost:36.59 cc, CTV Quadrant:285.07 cc, CTV NT:210.1 cc and CTV MISS:13.57 cc. Only 50.6% (125) of the patients presented the CTV Boost completely inside the CTV Quadrant and in 47.3% (117), partially inside. Among patients with any CTV MISS, 80.3% (98) had 10% or more of CTV Boost outside the treatment volume. Regarding CTV MISS, there were no statistically significant differences between the groups with 1 clip versus 2 or more clips, nor between patients with or without reconstructive surgery. In average, the CTV Boost was 87% smaller than the CTV Quadrant. The whole quadrant irradiation would lead to unnecessary irradiation of 26% of normal breast tissue.
Conclusion:
Surgical bed clipping is up most important in the definition of the boost volume irradiation to ensure precision minimizing geographical miss and optimizing surrounding normal tissue sparing.
Related Concept Videos
Conservation of Energy in Control Volume
For steady flow systems, the time derivative of the stored energy becomes zero since there is no energy accumulation within the control volume. This simplifies the energy equation to:
Conservation of Mass in Finite Cotrol Volume
A system is defined as a collection of unchanging contents, and the conservation of mass states that a system's mass is constant.
Conservation of Mass in Moving, Nondeforming Control Volume
In the context of a detention basin, the conservation of mass states that the total mass of water entering the basin must equal the mass leaving the basin plus any accumulation of...
Conservation of Mass in Fixed, Nondeforming Control Volume
In the case of a sewer pipe, which can be modeled...
What is Conservation Biology?
Conservation of Small Populations