Related Experiment Video
Updated: Feb 7, 2026

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
Published on: June 21, 2024
Substantial variation exists in spirometry interpretation practices for airflow obstruction in accredited lung
Nicolette R Holt1, Bruce R Thompson1, Belinda Miller1
1Department of Respiratory Medicine, The Alfred Hospital, Melbourne, Victoria, Australia.
Background:
Spirometry forms the foundation investigation for the diagnosis and monitoring of common pulmonary conditions. However, potential variation in spirometry interpretation for airflow obstruction may impact subsequent clinical management.
Aim:
To audit spirometry interpretation practices for airflow obstruction in Thoracic Society of Australia and New Zealand accredited laboratories.
Methods:
Thirty-nine accredited complex lung function laboratories were invited to participate in an online survey. The survey enquired about demographics, definition of lower limit of normal range for spirometry parameters, spirometric parameters used for identifying airflow obstruction, spirometric definition of airflow obstruction, definition of significant bronchodilator response and chosen spirometry reference equations.
Results:
Thirty-six laboratories provided complete responses (response rate, 92%). To define the lower limit of normal, 26 of 36 used the 5th percentile, 7 of 36 used a fixed cut-off and 3 used other. Twenty-nine laboratories utilised forced expiratory volume in 1 s/forced vital capacity (FEV1 /FVC) as the sole parameter to identify airflow obstruction, 3 of 36 used FEV1 /FVC and FEF25-75% , and 4 used other. To define airflow obstruction, 25 of 36 laboratories used FEV1 /FVC < 5th percentile, 9 of 36 used a fixed cut-off (FEV1 /FVC < 0.7, 6/36; FEV1 /FVC < 0.8, 2/36; FEV1 /FVC < 0.75, 1/36) and 2 of 36 used other. Twenty-six laboratories defined a significant bronchodilator response as an increase of at least 200 mL and 12% in FEV1 and/or FVC, 9 of 36 used ≥200 mL and ≥ 12% increase in FEV1 only, and 1 used other criteria. Reference equations utilised for interpretation of spirometry data included: Quanjer 2012 Global Lung Initiative (16/36), the third National Health and Nutritional Examination Survey (8/36), European Community of Coal and Steel (8/36) and other (4/36).
Conclusions:
Significant heterogeneity in spirometry interpretation for airflow obstruction exists across Australian and New Zealand accredited lung function laboratories. Lack of standardisation may translate into clinically appreciable differences for the diagnosis and management of common respiratory conditions. Ongoing discussion regarding formal standardisation is required.
More Related Videos
Related Concept Videos
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...
Lung Capacity
Conservative Site-specific Recombination and Phase Variation
The recognition sites for Cre recombinase called LoxP...
Variation of Atmospheric Pressure
Assuming the air temperature is constant at a given altitude and that the ideal gas law of thermodynamics describes the atmosphere to a good approximation, one can find the variation of atmospheric pressure with height.
Let p(y) be the atmospheric pressure at...
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...

