Related Experiment Video
Updated: Feb 7, 2026

Effects of Allogeneic Platelet-Rich Plasma PRP on the Healing Process of Sectioned Achilles Tendons of Rats: A Methodological Description
Published on: March 19, 2018
Different mechanisms activated by mild versus strong loading in rat Achilles tendon healing
Malin Hammerman1, Franciele Dietrich-Zagonel1, Parmis Blomgran1
1Experimental orthopedics, Department of Clinical and Experimental Medicine, Faculty of Health Science, Linköping University, Linköping, Sweden.
Background:
Mechanical loading stimulates Achilles tendon healing. However, various degrees of loading appear to have different effects on the mechanical properties of the healing tendon, and strong loading might create microdamage in the tissue. This suggests that different mechanisms might be activated depending on the magnitude of loading. The aim of this study was to investigate these mechanisms further.
Methods:
Female rats had their right Achilles tendon cut transversely and divided into three groups: 1) unloading (calf muscle paralysis by Botox injections, combined with joint fixation by a steel-orthosis), 2) mild loading (Botox only), 3) strong loading (free cage activity). Gene expression was analyzed by PCR, 5 days post-injury, and mechanical testing 8 days post-injury. The occurrence of microdamage was analyzed 3, 5, or 14 days post-injury, by measuring leakage of injected fluorescence-labelled albumin in the healing tendon tissue.
Results:
Peak force, peak stress, and elastic modulus of the healing tendons gradually improved with increased loading as well as the expression of extracellular matrix genes. In contrast, only strong loading increased transverse area and affected inflammation genes. Strong loading led to higher fluorescence (as a sign of microdamage) compared to mild loading at 3 and 5 days post-injury, but not at 14 days.
Discussion:
Our results show that strong loading improves both the quality and quantity of the healing tendon, while mild loading only improves the quality. Strong loading also induces microdamage and alters the inflammatory response. This suggests that mild loading exert its effect via mechanotransduction mechanisms, while strong loading exert its effect both via mechanotransduction and the creation of microdamage.
Conclusion:
In conclusion, mild loading is enough to increase the quality of the healing tendon without inducing microdamage and alter the inflammation in the tissue. This supports the general conception that early mobilization of a ruptured tendon in patients is advantageous.
Related Concept Videos
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
Strong Acid and Base Solutions
Titration of a Strong Acid with a Strong Base
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
Titration of a Weak Base with a Strong Acid
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Titration of a Weak Acid with a Strong Base

