Agnieszka Dyrda1,2, Ana Martínez-Palmer1, Daniel Martín-Moral1
1Department of Ophthalmology, Hospital Universitario del Mar and Hospital de la Esperanza, Pompeu and Fabra University, Barcelona, Spain.
Purpose:
To present the outcomes of hybrid multifocal and monofocal intraocular lenses (IOLs) and to compare with refractive and diffractive multifocal IOLs (MFIOLs).
Methods:
Three hundred twenty eyes (160 patients) underwent cataract surgery with randomized IOLs bilateral implantation. Changes in uncorrected and distance-corrected logMAR distance, intermediate and near (UNVA and DCNVA) visual acuity (VA), contrast sensitivity (CS), presence of dysphotopsia, spectacle independence, and patient satisfaction were analyzed.
Results:
Postoperative VA in the hybrid (OptiVis) group was improved in all distances (p < 0.001). OptiVis acted superiorly to monofocal IOLs in UNVA and DCNVA (p < 0.001 for both) and to refractive ones in DCNVA (p < 0.005). Distance, mesopic, without glare CS in OptiVis was lower than in the monofocal group and similar to other MFIOLs. No differences in dysphotopsia pre- and postoperatively and spectacle independence in near for OptiVis and refractive MFIOLs were detected. OptiVis patients were more satisfied than those with monofocal IOLs (p=0.015).
Conclusions:
After cataract surgery, patients with OptiVis improved VA in all distances. Near and intermediate VA was better than monofocal, and DCNVA was better than the refractive group. CS was lower in OptiVis than in the monofocal group, but there was no difference between MFIOLs. Patient satisfaction was higher in OptiVis than in the monofocal group. This trial is registered with NCT03512626.
Related Concept Videos
Interference and Diffraction
Hybrid Zones
Hybridization of Atomic Orbitals I
Hybridization of Atomic Orbitals II
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Influence of Earth's Curvature and Atmospheric Refraction on Leveling