Related Experiment Video
Updated: Feb 7, 2026

A Magnetic Microbead Occlusion Model to Induce Ocular Hypertension-Dependent Glaucoma in Mice
Published on: March 23, 2016
Induction of significant intraocular pressure diurnal fluctuation in rats using a modified technique of microbead
Lin Fu1,2, Jimmy Shiu Ming Lai2, Amy Cheuk Yin Lo2
1Affiliated Eye Hospital, School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou 325035, Zhejiang Province, China.
Aim:
To investigate the effect of microbead iridocorneal angle occlusion on intraocular pressure (IOP) diurnal fluctuation in rat eyes.
Methods:
Male Dark Agouti (DA) rats, 8-10 week old, were each given a single intracameral injection of microbeads, followed by injection of dispersive viscoelastic solution. The right eye served as the experimental eye, while the left eye served as the control. IOP was measured twice daily postoperatively for 3wk and compared between groups. At the end of 3wk, the rats were sacrificed and the eyes were harvested for histological analysis and retinal ganglion cell (RGC) counting.
Results:
After microbead injection, experimental eyes had significantly higher dark time IOP than controls from the second week to the third week [2nd week: 22.92±1.631 mm Hg (n=5) vs 17.35±0.751 mm Hg (n=5); 3rd week: 23.59±1.494 mm Hg vs 17.73±0.592 mm Hg (n=5)], while light time IOP was comparable between groups. The fluctuation levels of IOP in the experimental eyes were 7.21±0.398 mm Hg (n=5), 9.50±1.017 mm Hg (n=5) and 10.66±0.894 mm Hg (n=5) from the first week to the third week after injection. Comparatively, they were significantly lower in the control eyes, which were 4.69±0.323 mm Hg (n=5), 2.84±1.122 mm Hg (n=5) and 4.98±0.603 mm Hg (n=5) respectively. However, at the end of 3wk, the larger fluctuations in IOP in the experimental eyes was not associated with a significant loss of RGCs.
Conclusion:
Microbead occlusion exacerbates diurnal IOP fluctuation in rats. This reported model may serve as a method of investigating the pathological effects of IOP fluctuation. A longer observation period, or repeated injections, may be needed to observe a significant change in RGC density.
More Related Videos
04:38A Middle Cerebral Artery Occlusion Technique for Inducing Post-stroke Depression in Rats
Published on: May 22, 2019
09:08Induction of Ischemic Stroke and Ischemia-reperfusion in Mice Using the Middle Artery Occlusion Technique and Visualization of Infarct Area
Published on: February 2, 2017
Related Concept Videos
Vapor Pressure
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Induction
A...
Constant Pressure Calorimetry
Self-Inductance
Consider a circuit connected to an AC source. As the current varies with time, the magnetic flux through the circuit correspondingly changes. Faraday's law tells us that an emf would...
Vapor Pressure Lowering