Related Experiment Video
Updated: Feb 7, 2026

C-arm-Free Simultaneous OLIF51 and Percutaneous Pedicle Screw Fixation in a Single Lateral Position
Published on: September 16, 2022
[Real-Time Monitoring Method for Pedicle Screw Fixation Surgery Based on Near-Infrared Spectrum and Computer
Abstract:
Spine is one of the most important organs in the human body. One of the most commonly used method for the treatment of spinal diseases is the internal fixation and accurate placement of pedicle screw, which is a key factor of spinal surgery. However, due to the large differences as to the appearance of pedicles, it is hard to place the pedicle screw precisely, which will cause complication. Therefore, to find a new real-time intra-operative monitoring method with navigation is the direction of clinical application research. In this paper, a new method was firstly proposed. This method combined computer tomography (CT) values and near-infrared spectroscopy (NIRs) measurement data to guide the PS placement, and the relationship between NIRs parameters and CT values along the PS trajectory in vertebrae was investigated. First, we took pig vertebrae as samples and different puncture paths were planned. Second, a near-infrared monitoring device was utilized in experiments of fresh pig vertebrae to acquire the best NIRs monitoring pattern factors. Finally, the correlation function between NIRs data and CT values pattern factors was obtained. The results showed that CT values have a linear relationship with NIRs monitoring pattern factors, which provide references for real-time monitoring method in pedicle screw fixation surgery. This model can be applied in monitoring the pedicle screw implantation and alarming. The proposed method will be potential in improving the accuracy of PS placement and reduce the risk caused by the misplacement of pedicle screw.
Related Concept Videos
The Electromagnetic Spectrum
The Electromagnetic Spectrum
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
Screw: Problem Solving
To evaluate the...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
IR Spectrum
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0%...

