A NEWLY DEVELOPED PHANTOM FOR PHYSICAL QUALITY ASSURANCE OF DENTAL CONE-BEAM COMPUTED TOMOGRAPHY
Junko Bamba1, Hideki Ishida1, Kazuyuki Araki1
1Division of Radiology, Department of Oral Diagnostic Sciences, Showa University School of Dentistry, 2-1-1 Kitasenzoku, Ota-ku, Tokyo, Japan.
Abstract:
Two phantoms for a performance evaluation of cone-beam computed tomography (CBCT) were developed and their efficiency was tested. The first phantom, for low-contrast resolution, consisted of an acrylic circular plate with three 0.5-1.0 mm diameter rods. These rods enable the user to visually evaluate the limit of observation. The second phantom, for geometric distortion, especially focused on the z-axis and consisted of two tabular acryl plates crossed perpendicularly with 1.0 mm-wide grooves in a grating form every 10.0 mm. The distances between the grooves on the axial and coronal images were evaluated. Five CBCT modalities were assessed using these phantoms. The contrast resolutions differed for each apparatus and set of exposure parameters. In terms of geometric distortion, some distortion was observed at the periphery of the field of view for both the axial and z-axis planes. These results suggest that our new phantoms can be used to evaluate CBCT.
More Related Videos
06:33Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
10:23Author Spotlight: Three-Dimensional Cephalometric Landmark Annotation Demonstration on Human Cone Beam Computed Tomography Scans
Published on: September 8, 2023
Related Concept Videos
Quality Assurance
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Physical and Chemical Properties of Matter
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...