Related Experiment Video
Updated: Feb 7, 2026

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
Published on: May 25, 2020
Use of Machine Learning on Contact Lens Sensor-Derived Parameters for the Diagnosis of Primary Open-angle Glaucoma
Keith R Martin1, Kaweh Mansouri2, Robert N Weinreb2
1Department of Ophthalmology, Cambridge University Hospitals NHS Foundation Trust, Cambridge, United Kingdom.
Purpose:
To test the hypothesis that contact lens sensor (CLS)-based 24-hour profiles of ocular volume changes contain information complementary to intraocular pressure (IOP) to discriminate between primary open-angle glaucoma (POAG) and healthy (H) eyes.
Design:
Development and evaluation of a diagnostic test with machine learning.
Methods:
Subjects: From 435 subjects (193 healthy and 242 POAG), 136 POAG and 136 age-matched healthy subjects were selected. Subjects with contraindications for CLS wear were excluded.
Procedure:
This is a pooled analysis of data from 24 prospective clinical studies and a registry. All subjects underwent 24-hour CLS recording on 1 eye. Statistical and physiological CLS parameters were derived from the signal recorded. CLS parameters frequently associated with the presence of POAG were identified using a random forest modeling approach.
Main Outcome Measures:
Area under the receiver operating characteristic curve (ROC AUC) for feature sets including CLS parameters and Start IOP, as well as a feature set with CLS parameters and Start IOP combined.
Results:
The CLS parameters feature set discriminated POAG from H eyes with mean ROC AUCs of 0.611, confidence interval (CI) 0.493-0.722. Larger values of a given CLS parameter were in general associated with a diagnosis of POAG. The Start IOP feature set discriminated between POAG and H eyes with a mean ROC AUC of 0.681, CI 0.603-0.765. The combined feature set was the best indicator of POAG with an ROC AUC of 0.759, CI 0.654-0.855. This ROC AUC was statistically higher than for CLS parameters or Start IOP feature sets alone (both P < .0001).
Conclusions:
CLS recordings contain information complementary to IOP that enable discrimination between H and POAG. The feature set combining CLS parameters and Start IOP provide a better indication of the presence of POAG than each of the feature sets separately. As such, the CLS may be a new biomarker for POAG.
Related Concept Videos
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment
Glaucoma: Overview
Contact-dependent Signaling
Gap Junctions
In animal cells, gap junctions are formed...
Machines
A free-body diagram of the...