Quantification of ondansetron, granisetron and tropisetron in goat plasma using hydrophilic interaction liquid chromatography-solid phase extraction coupled with hydrophilic interaction liquid chromatography-triple quadrupole tandem mass spectrometry
Related Experiment Video
Updated: Feb 7, 2026

Quantitative Metabolomics of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: January 5, 2021
Cunying Huang1, Huihui Wan1, Jing Zhang1
1Faculty of Chemical, Environmental and Biological Science and Technology, Analytical Center, Dalian University of Technoloy, Dalian 116024, China.
Abstract:
An assay method to quantify ondansetron (OND), granisetron (GRA) and tropisetron (TRO) in goat plasma has been successfully developed and validated. This method procedure for the analysis of OND, GRA and TRO was involved of extracting samples with hydrophilic interaction liquid chromatography (HILIC) solid phase extraction (SPE) and determination by liquid chromatography coupled to tandem mass spectroscopy. An SPE method for the simultaneous extraction of OND, GRA and TRO with high efficiency and selectivity was developed. Prior to HPLC-MS/MS analysis, most of the sources of interference present in the supernatant after protein precipitation of plasma proteins was efficiently removed from the samples by the HILIC SPE treatment. For the quantification of OND, GRA and TRO in the samples, tandem mass spectrometry operating in positive electrospray ionization mode with multiple reaction monitoring was used. The calibration curve was performed in the range of 0.2-20 ng/mL for the target OND, GRA and TRO in goat plasma samples. The precision of the intra- and inter-day assay for OND, GRA and TRO were 1.84-6.23% and 3.89-5.31%, 2.63-6.29% and 3.76-5.31%, 1.99-5.67% and 2.64-4.70%, respectively. The accuracy of the intra- and inter-day assay for OND, GRA and TRO were 89.15-97.39% and 89.46-95.17%, 91.08-100.82% and 91.24-99.47%, 92.30-100.74% and 94.21-97.90%, respectively. For the determination of OND, GRA and TRO in plasma samples, no significant matrix effects were observed. The mean absolute recoveries were 103-150%, 115-121%, and 98-141% for OND, GRA and TRO, respectively. Furthermore, the mean process efficiency values of silica SPE were 98-135%, 92-124%, and 72-109% for OND, GRA and TRO, respectively.
More Related Videos
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
08:14Extraction of Non-Protein Amino Acids from Cyanobacteria for Liquid Chromatography-Tandem Mass Spectrometry Analysis
Published on: December 9, 2022
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Molecular Comparison of Gases, Liquids, and Solids