Related Experiment Video
Updated: Feb 7, 2026

Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 18, 2020
Early and Mid-Term Results of Rapid Deployment Valves: The Intuity Italian Registry (INTU-ITA)
Augusto D'Onofrio1, Chiara Tessari1, Claudia Filippini2
1Department of Cardiac Surgery, University of Padova, Padova, Italy.
Background:
Rapid deployment bioprostheses (RDBs) have been recently introduced into clinical practice for the treatment of severe aortic valve stenosis. The aim of this retrospective multicenter study was to assess early and mid-term clinical and hemodynamic outcomes of patients undergoing RDB implantation.
Methods:
Data from a national registry that included patients who underwent isolated or combined aortic valve replacement with RDB in Italy were analyzed. Definitions of the European System for Cardiac Operative Risk Evaluation were used for preoperative variables and updated definitions from the Valve Academic Research Consortium were used for postoperative outcomes assessment. Univariable and multivariable analyses were performed to identify independent predictors of mortality. Follow-up was performed with clinical and echocardiographic examinations at each study site and, if this was not possible, through telephonic interviews. The Kaplan-Meier method was used for survival analysis.
Results:
A total of 902 patients (December 2012 through November 2017) from 20 national centers were included in the registry. Device success was 95.9%, and 30-day all-cause mortality was 2.8%. Postoperative pacemaker implantation was needed in 63 patients (6.9%). At discharge, peak and mean transaortic gradients were 19 ± 7 mm Hg and 11 ± 4 mm Hg, respectively. Mild and moderate aortic regurgitation were found in 71 patients (8.2%) and in 10 patients (1.2%), respectively. Median follow-up time was 357 days (interquartile range: 103 to 638 days). Survival at 4 years was 86% ± 1%. Preoperative conduction disturbances and history of previous myocardial infarction were independently associated with mortality.
Conclusions:
Aortic RDBs provide good early and mid-term clinical and hemodynamic outcomes. These devices may be considered as a reasonable alternative to conventional bioprostheses, especially in minimally invasive and combined operations.
More Related Videos
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Long-term Depression
Long-term Depression
Calcium Ion Concentration Mechanism
If over...
Mitral Valve Prolapse I: Introduction
Long-term Potentiation
Long-term Potentiation
Hebbian LTP
LTP can occur when...