Related Experiment Video
Updated: Feb 7, 2026

Next Generation Sequencing for the Detection of Actionable Mutations in Solid and Liquid Tumors
Published on: September 20, 2016
Describing the Reportable Range Is Important for Reliable Treatment Decisions: A Multiple Laboratory Study for
Véronique Tack1, Lien Spans2, Ed Schuuring3
1Biomedical Quality Assurance Research Unit, Department of Public Health and Primary Care, University of Leuven, Leuven, Belgium.
Abstract:
Because interpretation of next-generation sequencing (NGS) data remains challenging, optimization of the NGS process is needed to obtain correct sequencing results. Therefore, extensive validation and continuous monitoring of the quality is essential. NGS performance was compared with traditional detection methods and technical quality of nine NGS technologies was assessed. First, nine formalin-fixed, paraffin-embedded patient samples were analyzed by 114 laboratories by using different detection methods. No significant differences in performance were observed between analyses with NGS and traditional techniques. Second, two DNA control samples were analyzed for a selected number of variants by 26 participants with the use of nine different NGS technologies. Quality control metrics were analyzed from raw data files and a survey about routine procedures. Results showed large differences in coverages, but observed variant allele frequencies in raw data files were in line with predefined variant allele frequencies. Many false negative results were found because of low-quality regions, which were not reported as such. It is recommended to disclose the reportable range, the fraction of targeted genomic regions for which calls of acceptable quality can be generated, to avoid any errors in therapy decisions. NGS can be a reliable technique, only if essential quality control during analysis is applied and reported.
More Related Videos
Related Concept Videos
Next-generation Sequencing
Next-Generation Sequencing Methods
Although all next-generation methods use different technologies, they all share a set of standard features....
Reliability and Validity
Multiple Allele Traits
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
Serum Laboratory Studies, Stool Test, Breath Test
Bioavailability Study Design: Single Versus Multiple Dose Studies