Related Experiment Video
Updated: Feb 7, 2026

Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Published on: February 8, 2022
Short communication: Validation of methods for practically evaluating failed passive transfer of immunity in calves
D L Renaud1, T F Duffield1, S J LeBlanc1
1Department of Population Medicine, University of Guelph, Guelph, Ontario N1G 2W1, Canada.
Abstract:
Providing a sufficient quantity of high-quality colostrum to male and female calves soon after birth is critical to reduce the risk of disease and mortality. Practical tests have not been validated to determine failed passive transfer of immunity upon arrival at veal facilities. There are many challenges to validation, including the lack of information on the age of the calf and the high prevalence of dehydration. The objective of this study was to validate a semiquantitative IgG antibody test using whole blood and a digital refractometer using serum to determine passive transfer of immunity status. A total of 149 Holstein calves were evaluated upon arrival at a milk-fed veal facility for dehydration status and had blood drawn to evaluate passive transfer of immunity. Serum IgG determined by radial immunodiffusion was used as the gold standard for the validation of the tests, and a cut-off point of <1,000 mg/dL of IgG was used to indicate failed passive transfer of immunity. Serum total protein (STP) was evaluated using a digital refractometer (Misco Palm Abbe no. PA202x, Misco, Solon, OH), and a semiquantitative test (ZAPvet Bovine IgG test, NOWDiagnostics, Toronto, Ontario, Canada) was used on whole blood. A nonparametric receiver operating characteristic curve was generated to compare STP and IgG levels. Sensitivity, specificity, positive predictive values, and negative predictive values were calculated for STP and the semiquantitative IgG test. A total of 31 calves (21%) had serum IgG <1,000 mg/dL. Twelve percent of calves were showing signs of clinical dehydration when assessed upon arrival. The serum total protein (STP) was very well correlated with the concentration of IgG (R2 = 0.75). The STP cut point to determine passive transfer was ≥5.1 g/dL, yielding a sensitivity of 84% and a specificity of 90%. The semiquantitative antibody test on whole blood performed poorly, with a sensitivity of 77% and a specificity of 44%. This study demonstrates that serum total protein is a reliable measure for evaluating passive transfer of immunity and can be used despite a high prevalence of dehydration.
Related Concept Videos
Active versus Passive Immunity
Active Immunity
Active immunity refers to the resistance one develops...
Communication
Communication
Techniques of therapeutic communication I: Active Listening, Sharing Observations, Validation, and Using Touch
Therapeutic communication is not the same as social interaction. Social interaction has no goal or purpose and consists of casual information sharing, whereas therapeutic communication has a plan or purpose for the conversation. Therapeutic...
Hypothesis: Accept or Fail to Reject?
There are two ways to indicate that the null hypothesis is not rejected. 'Accept' the null...
Reliability and Validity

