Development and Testing of a Novel Anaesthesia Induction/Ventilation Protocol for Patients With Cardiogenic Shock

Athanasios Chalkias1, Fotios Pavlopoulos2, Effie Papageorgiou3

  • 1University of Thessaly, School of Health Sciences, Faculty of Medicine, Department of Anesthesiology and Perioperative Medicine, Larisa, Greece; Hellenic Society of Cardiopulmonary Resuscitation, Athens, Greece.

Abstract

Related Concept Videos

Mechanical Ventilation II: Invasive Ventilation01:23

Mechanical Ventilation II: Invasive Ventilation

Ventilators are essential medical equipment used to aid patients with respiratory difficulties. Their primary function is to assist or replace spontaneous breathing by providing mechanical ventilation. There are two general classes of mechanical ventilators: negative-pressure and positive-pressure ventilators.
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
774
Mechanical Ventilation III: Noninvasive Ventilation01:23

Mechanical Ventilation III: Noninvasive Ventilation

Noninvasive positive-pressure ventilation (NIPPV), continuous positive airway pressure (CPAP), and bilevel positive airway pressure (BiPAP) are essential methods in respiratory care. These ventilation techniques offer unique benefits for patients with various respiratory conditions, providing adequate support without requiring intubation. Let's explore how each method is crucial in improving patient outcomes and enhancing respiratory therapy.
Noninvasive Positive-Pressure Ventilation...
606
Shock Waves01:16

Shock Waves

While deriving the Doppler formula for the observed frequency of a sound wave, it is assumed that the speed of sound in the medium is greater than the source's speed through it. When this condition is breached, a shock wave occurs.
When the source's speed approaches the speed of sound, constructive interference between successive wavefronts emitted by the source occurs immediately behind it. Initially, scientists believed that this constructive interference would result in such high...
2.6K
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
865
Factors Affecting Pulmonary Ventilation01:19

Factors Affecting Pulmonary Ventilation

Besides the pressure difference between the external environment and the lungs, the airflow rate and ease of pulmonary ventilation are also influenced by three other factors: surface tension of the fluid in the alveoli, compliance of the lungs, and airway resistance.
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
3.2K
In Vitro Drug Release Testing: Overview, Development and Validation01:10

In Vitro Drug Release Testing: Overview, Development and Validation

In vitro dissolution and drug release tests assess how quickly and how much of a drug is released from its dosage form into an aqueous medium under standardized laboratory conditions. These tests are essential tools in pharmaceutical development and quality assurance, offering insight into the drug's performance before clinical use.During formulation development, dissolution testing identifies incomplete or inconsistent drug release issues. It also supports decisions on selecting the optimal...
357