Related Experiment Video
Updated: Feb 7, 2026

Assessment of Myofilament Ca2+ Sensitivity Underlying Cardiac Excitation-contraction Coupling
Published on: August 1, 2016
Excitation-Contraction Coupling Time is More Sensitive in Evaluating Cardiac Systolic Function
Juan Gao1, Min Zhu1, Hai-Yi Yu1
1Department of Cardiology and Institute of Vascular Medicine, Peking University Third Hospital, Key Laboratory of Cardiovascular Molecular Biology and Regulatory Peptides, Ministry of Health, Key Laboratory of Molecular Cardiovascular Science, Ministry of Education, Beijing Key Laboratory of Cardiovascular Receptors Research, Beijing 100191, China.
Background:
Pressure overload-induced myocardial hypertrophy is a key step leading to heart failure. Previous cellular and animal studies demonstrated that deteriorated excitation-contraction coupling occurs as early as the compensated stage of hypertrophy before the global decrease in left ventricular ejection fraction (LVEF). This study was to evaluate the cardiac electromechanical coupling time in evaluating cardiac systolic function in the early stage of heart failure.
Methods:
Twenty-six patients with Stage B heart failure (SBHF) and 31 healthy controls (CONs) were enrolled in this study. M-mode echocardiography was performed to measure LVEF. Tissue Doppler imaging (TDI) combined with electrocardiography (ECG) was used to measure cardiac electromechanical coupling time.
Results:
There was no significant difference in LVEF between SBHF patients and CONs (64.23 ± 8.91% vs. 64.52 ± 5.90%; P = 0.886). However, all four electromechanical coupling time courses (Qsb: onset of Q wave on ECG to beginning of S wave on TDI, Qst: onset of Q wave on ECG to top of S wave on TDI, Rsb: top of R wave on ECG to beginning of S wave on TDI, and Rst: top of R wave on ECG to top of S wave on TDI) of SBHF patients were significantly longer than those of CONs (Qsb: 119.19 ± 35.68 ms vs. 80.30 ± 14.81 ms, P < 0.001; Qst: 165.42 ± 60.93 ms vs. 129.04 ± 16.97 ms, P = 0.006; Rsb: 82.43 ± 33.66 ms vs. 48.30 ± 15.18 ms, P < 0.001; and Rst: 122.37 ± 36.66 ms vs. 93.25 ± 16.72 ms, P = 0.001), and the Qsb, Rsb, and Rst time showed a significantly higher sensitivity than LVEF (Rst: P =0.032; Rsb: P = 0.003; and Qsb: P = 0.004).
Conclusions:
The cardiac electromechanical coupling time is more sensitive than LVEF in evaluating cardiac systolic function.
More Related Videos
Related Concept Videos
Excitation-Contraction Coupling in Skeletal Muscles
When an action...
Muscle Contraction
Muscle Contraction
Smooth Muscle Contraction
The onset of contraction is triggered by an increase in calcium ions within the sarcoplasm, similar to the process in striated muscle. However, smooth muscles have a relatively smaller reservoir of the sarcoplasmic...
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...
Spin–Spin Coupling: Three-Bond Coupling (Vicinal Coupling)
The extent of coupling depends on the C‑C bond length, the two H‑C‑C angles, any electron-withdrawing substituents, and the dihedral angle between the involved orbitals. The...

