Related Experiment Video
Updated: Feb 7, 2026

Assessment of Physical Activity Intensity with Accelerometers and Oxygen Consumption
Published on: June 20, 2025
A comparison of physical activity from Actigraph GT3X+ accelerometers worn on the dominant and non-dominant wrist
Duncan S Buchan1, Fiona McSeveney1, Gillian McLellan1
1Institute of Clinical Exercise and Health Science, The University of the West of Scotland, Hamilton, UK.
Abstract:
The purpose of this study was to evaluate the agreement between several activity measures using raw acceleration data from accelerometers worn concurrently on the dominant and non-dominant wrist. Fifty-five adults (31·9 ± 9·7 years, 26 males) wore two ActiGraph GT3X+ monitors continuously for 1 day, one on their non-dominant wrist and the other on their dominant wrist. Paired t-tests were undertaken with sequential Holm-Bonferroni corrections to compare wear time, moderate-vigorous physical activity (MVPA), time spent in 10-min bouts of MVPA (MVPA10 min ) and the average magnitude of dynamic wrist acceleration (ENMO). Level of agreement between outcome variables from the wrists was examined using intraclass correlation coefficients (ICC, single measures, absolute agreement) with 95% confidence intervals and limits of agreement (LoA). Time spent across acceleration levels in 40 mg resolution were also examined. There were no significant differences between the non-dominant and dominant wrist for ENMO, wear time, MVPA or MVPA10 min . Agreement between wrists was strong for most outcomes (ICC ≥0·92) including wear time, ENMO, MVPA, MVPA10 min and the distribution of time across acceleration levels. Agreement was strong in the low acceleration bands (ICC = 0·970 and 0·922) with a mean bias of 3·08 min (LoA -55·18 to 61·34) and -5·43 (LoA -43·47 to 32·62). In summary, ENMO, MVPA, MVPA10 min , wear time and the distribution of time across acceleration levels compared well at the group level. The LOA from the two lowest acceleration levels suggest further work over a longer monitoring period is needed to determine whether outputs from each wrist are comparable.
Related Concept Videos
Incomplete Dominance
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Physical and Chemical Properties of Matter
Physical Pendulum
When dealing with complicated systems, the mass moment of inertia is an important parameter, as it...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
The Scope of Physics

