Related Experiment Video
Updated: Feb 7, 2026

Reverse Total Shoulder Arthroplasty
Published on: July 5, 2011
Reverse shoulder arthroplasty for proximal humerus fractures: Is the glenoid implant problematic?
Arthur Lignel1, Julien Berhouet2, Marc-Alexandre Loirat1
1CHU Pontchaillou, 35000 Rennes, France.
Introduction:
Reverse shoulder arthroplasty (RSA) is a key tool in the orthopedic trauma surgeon's arsenal, especially when faced with a proximal humerus fracture in older patients. However, few studies have focused on the glenoid side of RSA in this indication as the implant is placed in a generally healthy scapula.
Hypothesis:
Glenoid implants for RSA after trauma are well positioned and do not often cause complications.
Material And Methods:
Retrospective multicenter study of 513 patients who underwent RSA because of a proximal humerus fracture. The mean follow-up was 55 months. Radiographs were used to assess the height and tilt of the glenoid implant, along with the development of scapular notching or loosening. The clinical outcomes were determined based on the Constant score.
Results:
At the last follow-up, 44% of shoulders had scapular notching, 7% of which were severe (stages 3-4). This notching was progressive, with two resulting in loosening. The rate of severe notching was higher in patients with a high glenoid implant (62.5% vs. 42.3%, p=0.03) or glenosphere with superior tilt (58.3% vs. 37.8%, p=0.02). Nine patients had confirmed loosening and 63 had potential loosening. This was more common in cases with superior tilt (9.3% vs. 0.4%, p<0.001). Patients with a high glenoid implant had a lower Constant score (57 vs. 45, p<0.001). There fewer cases of severe notching when a lateralized glenoid implant was used (0% vs. 7%, p<0.05) and/or the humeral implant had a smaller neck-shaft angle (implants<155°: 3% vs. implants at 155°: 8.5%, p=0.03).
Discussion And Conclusion:
Glenoid loosening and severe scapular notching are related to poor positioning and/or incorrect orientation of the glenosphere. Implant selection is important, as there is little to no notching when less-angled humeral implants and lateralized glenoid implants are used.
Level Of Evidence:
IV.
Related Concept Videos
Muscles of the Shoulder
Anterior Thoracic Muscles
The anterior thoracic muscles include the serratus anterior, subclavius, and...
Bones of the Upper Limb: Humerus
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Factors Influencing Attraction I: Proximity
Reversible and Irreversible Processes
Diode: Reverse bias