The mechanical response of the mouse cervix to tensile cyclic loading in term and preterm pregnancy

C Jayyosi1, N Lee1, A Willcockson2

  • 1Department of Mechanical Engineering, Columbia University, New York, NY 10027, USA.

Acta Biomaterialia
|July 31, 2018
PubMed

A well-timed modification of both the collagen and elastic fiber network in the cervix during pregnancy accompanies the evolution of tissue mechanical parameters that are key to a successful pregnancy. Understanding of the cervical mechanical behaviour along normal and abnormal pregnancy is crucial to define the molecular events that regulate remodeling in term and preterm birth (PTB). In this study, we measured the mechanical response of mouse cervical tissue to a history of cyclic loading and quantified the tissue's ability to recover from small and large deformations. Assessments were made in nonpregnant, pregnant (gestation days 6, 12, 15 and 18) and mouse models of infection mediated PTB treated with lipopolysaccharide on gestation d15 (LPS treated) and hormone withdrawal mediated PTB on gestation d15 (RU486 treated). The current study uncovers the contributions of collagen and elastic fiber networks to the progressive change in mechanical function of the cervix through pregnancy. Premature cervical remodeling induced on gestation day 15 in the LPS infection model is characterized by distinct mechanical properties that are similar but not identical to mechanical properties at term ripening on day 18. Remodeling in the LPS infection model results in a weaker cervix, unable to withstand high loads. In contrast, the RU486 preterm model resembles the cyclic mechanical behaviour seen for term d18 cervix, where the extremely compliant tissue is able to withstand multiple cycles under large deformations without breaking. The distinct material responses to load-unload cycles in the two PTB models matches the differing microstructural changes in collagen and elastic fibers in these two models of preterm birth. Improved understanding of the impact of microstructural changes to mechanical performance of the cervix will provide insights to aid in the development of therapies for prevention of preterm birth.

Related Concept Videos

Uterus and Cervix01:18

Uterus and Cervix

The uterus, commonly called the womb, is a vital reproductive organ in females designed to provide a nurturing environment for the implantation and growth of an embryo. It is shaped like a hollow pear and positioned between the urinary bladder and the rectum. The uterus's structure allows it to support and protect a developing fetus throughout pregnancy.
The uterus is securely anchored within the pelvic cavity by paired broad ligaments on either side. It is further stabilized by three pairs...
5.1K
Long-term Depression01:05

Long-term Depression

Long-term depression, or LTD, is one of the ways by which synaptic plasticity—changes in the strength of chemical synapses—can occur in the brain. LTD is the process of synaptic weakening that occurs over time between pre and postsynaptic neuronal connections. The synaptic weakening of LTD works in opposition to synaptic strengthening by long-term potentiation (LTP) and together are the main mechanisms that underlie learning and memory.
33.3K
Cell-matrix's Response to Mechanical Forces01:13

Cell-matrix's Response to Mechanical Forces

In animal cells, the extracellular matrix allows cells within tissues to withstand external stresses and transmits signals from the outside of the cell to the inside. The extracellular matrix is extensive, and its composition varies between different types of tissues. For example, the reticular fibers and ground substance make up the ECM in loose connective tissue, while collagen and bone minerals make up the ECM of bone tissue. 
Anchoring junctions mechanically attach a cell to the...
3.6K
Tensile Strength Considerations of Concrete01:16

Tensile Strength Considerations of Concrete

Considering the tensile strength of concrete involves recognizing that the theoretical strength of cement paste can be up to a thousand times higher than what is observed in practical applications. This significant discrepancy is largely attributed to the presence of microscopic cracks within the concrete. These cracks tend to amplify stress at their tips when a load is applied, a phenomenon explained by Griffith's theory of brittle fracture.
The dimensions and shape of a concrete specimen...
558
Stereoisomerism of Cyclic Compounds02:33

Stereoisomerism of Cyclic Compounds

In this lesson, we delve into the role of ring conformation and its stability, which determines the spatial arrangement and, consequently, the molecular symmetry and stereoisomerism of cyclic compounds. 1,2-Dimethylcyclohexane is used as a case study to evaluate the possible number of stereoisomers. Here, given the multiple (n = 2) chiral centers, there are 2n = 4 possible configurations that lack a plane of symmetry, as the ring skeleton exists in a non-planar chair conformation. In addition,...
11.1K
Voltammetric Techniques: Cyclic Voltammetry01:10

Voltammetric Techniques: Cyclic Voltammetry

Cyclic voltammetry (CV) is an electrochemical technique used to investigate the redox properties of a chemical species. It involves measuring the current response of an electrochemical cell as a function of the applied potential. The setup for cyclic voltammetry typically consists of a working electrode, a reference electrode, and a counter electrode—all immersed in an electrolyte solution. The working electrode is where the redox reaction of interest occurs, while the reference electrode...
1.6K