The error of tensile strength tests and an approach for improvement
Michael Behr1, Jan Fuerst1, Martin Rosentritt1
1Department of Prosthodontics, Regensburg University Medical Center, 93042 Regensburg, Germany.
Objectives:
The deviation and spread of values measured by tensile strength tests should be significantly reduced by optimized axially pull-off-device.
Material And Methods:
Factors like geometry, roughness, surface texture and fit of the specimens, the luting procedure (mixing ratio, compacting pressure) were standardized and the precision of the axially load transmission during the tensile force application optimized. Copings of CoCr-alloy were luted using a provisional zinc-oxide eugenol and a glass-ionomer cement (n = 20 per group each) on 4°, respectively 8° titanium implant abutment analogs. 24 h after luting the copings were pulled off with the improved (IPD) and the previous non improved device (NIPD). Means, std. dev. and t-tests were calculated.
Results:
The stress- strain curves produced by the IPD showed a clear and linear relationship between stress and strain. The curves of the NIPD were ragged and chaotic. For both luting agents the means of the retentive force were considerable higher (p > 0.000) with IPD. However, the standard deviation was unimproved for the zinc oxide eugenol cement: IPD: 27%; NIPD: 27%, but significantly improved with glass ionomer: IPD: 16%, NIPD: 28%.
Conclusion:
The results from luting agents, which react like a solid body, may benefit from the optimized pull-off-device. Despite the fact that many factors in this investigation have been controlled, unknown flow characteristics of non-Newtonian-fluids like luting agents may have a considerable influence on the standard deviation of pull-off tests.
Related Concept Videos
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Relation Between Tensile Strength and Compressive Strength of Concrete
Errors In Hypothesis Tests
Non-destructive Tests for Concrete Strength
Accuracy and Errors in Hypothesis Testing
In hypothesis testing, the probability of making a Type I error, denoted as α, is commonly set at 0.05. This significance level indicates a 5%...
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...