Comparison of intracranial aneurysm flow quantification techniques: standard PIV vs stereoscopic PIV vs tomographic
Christoph Roloff1, Daniel Stucht2,3, Oliver Beuing3,4
1Department of Fluid Dynamics and Technical Flows, Otto von Guericke Universität Magdeburg, Magdeburg, Germany.
Abstract:
Image-based hemodynamic simulations to assess the rupture risk or improve the treatment planning of intracranial aneurysms have become popular recently. However, due to strong modeling assumptions and limitations, the acceptance of numerical approaches remains limited. Therefore, validation using experimental methods is mandatory.In this study, a unique compilation of four in-vitro flow measurements (three particle image velocimetry approaches using a standard (PIV), stereoscopic (sPIV), and tomographic (tPIV) setup, as well as a phase-contrast magnetic resonance imaging (PC-MRI) measurement) were compared with a computational fluid dynamics (CFD) simulation. This was carried out in a patient-specific silicone phantom model of an internal carotid artery aneurysm under steady flow conditions. To evaluate differences between each technique, a similarity index (SI) with respect to the velocity vectors and the average velocity magnitude differences among all involved modalities were computed.The qualitative comparison reveals that all techniques are able to provide a reasonable description of the global flow structures. High quantitative agreement in terms of SI and velocity magnitude differences was found between all PIV methods and CFD. However, quantitative differences were observed between PC-MRI and the other techniques. Deeper analysis revealed that the limited resolution of the PC-MRI technique is a major contributor to the experienced differences and leads to a systematic underestimation of overall velocity magnitude levels inside the vessel. This confirms the necessity of using highly resolving flow measurement techniques, such as PIV, in an in-vitro environment to individually verify the validity of the numerically obtained hemodynamic results.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Phase Diagrams
Phase Transitions
Aneurysm I: Introduction
Measurement: Standard Units