Patient-specific CFD modelling in the thoracic aorta with PC-MRI-based boundary conditions: A least-square
Rodrigo M Romarowski1, Adrien Lefieux2,3, Simone Morganti4
13D and Computer Simulation Laboratory, IRCCS Policlinico San Donato, San Donato Milanese, Italy.
Abstract:
The increasing use of computational fluid dynamics for simulating blood flow in clinics demands the identification of appropriate patient-specific boundary conditions for the customization of the mathematical models. These conditions should ideally be retrieved from measurements. However, finite resolution of devices as well as other practical/ethical reasons prevent the construction of complete data sets necessary to make the mathematical problems well posed. Available data need to be completed by modelling assumptions, whose impact on the final solution has to be carefully addressed. Focusing on aortic vascular districts and related pathologies, we present here a method for efficiently and robustly prescribing phase contrast MRI-based patient-specific data as boundary conditions at the domain of interest. In particular, for the outlets, the basic idea is to obtain pressure conditions from an appropriate elaboration of available flow rates on the basis of a 3D/0D dimensionally heterogeneous modelling. The key point is that the parameters are obtained by a constrained optimization procedure. The rationale is that pressure conditions have a reduced impact on the numerical solution compared with velocity conditions, yielding a simulation framework less exposed to noise and inconsistency of the data, as well as to the arbitrariness of the underlying modelling assumptions. Numerical results confirm the reliability of the approach in comparison with other patient-specific approaches adopted in the literature.
More Related Videos
14:14Targeting Neuronal Fiber Tracts for Deep Brain Stimulation Therapy Using Interactive, Patient-Specific Models
Published on: August 12, 2018
06:18Intravascular Ultrasound Image-Based Finite Element Modeling Approach for Quantifying In Vivo Mechanical Properties of Human Coronary Artery
Published on: December 6, 2024
Related Concept Videos
Thoracic Aorta
Electrostatic Boundary Conditions
The surface integral of an electric field is given by Gauss's law in integral form and is related to...
Magnetostatic Boundary Conditions
Boundary Conditions for Current Density
Boundary Conditions: Lossless Lines
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...
Electrostatic Boundary Conditions in Dielectrics
Consider a case where both the mediums across a boundary are two different dielectric materials. Recall that the electric field and electric displacement are proportional and related through the material's permittivity....
