Patient-specific CFD modelling in the thoracic aorta with PC-MRI-based boundary conditions: A least-square

Rodrigo M Romarowski1, Adrien Lefieux2,3, Simone Morganti4

  • 13D and Computer Simulation Laboratory, IRCCS Policlinico San Donato, San Donato Milanese, Italy.

Related Concept Videos

Thoracic Aorta01:15

Thoracic Aorta

The thoracic section of the aorta begins at the T5 vertebra and extends to the T12 level at the diaphragm, initially progressing through the mediastinum to the left of the spinal column. Throughout its course in the thoracic segment, the thoracic aorta emits various offshoots known collectively as visceral and parietal branches. The branches that predominantly supply blood to visceral organs are termed visceral branches and include bronchial, pericardial, esophageal, and mediastinal arteries,...
1.7K
Electrostatic Boundary Conditions01:16

Electrostatic Boundary Conditions

Consider an external electric field propagating through a homogeneous medium. When the electric field crosses the surface boundary of the medium, it undergoes a discontinuity. The electric field can be resolved into normal and tangential components. The amount by which the field changes at any boundary is given by the difference between the field components above and below the surface boundary.
The surface integral of an electric field is given by Gauss's law in integral form and is related to...
974
Magnetostatic Boundary Conditions01:28

Magnetostatic Boundary Conditions

An electric field suffers a discontinuity at a surface charge. Similarly, a magnetic field is discontinuous at a surface current. The perpendicular component of a magnetic field is continuous across the interface of two magnetic mediums. In contrast, its parallel component, perpendicular to the current, is discontinuous by the amount equal to the product of the vacuum permeability and the surface current. Like the scalar potential in electrostatics, the vector potential is also continuous...
1.7K
Boundary Conditions for Current Density01:25

Boundary Conditions for Current Density

Current density becomes discontinuous across an interface of materials with different electrical conductivities. The normal component of the current density is continuous across the boundary.
1.3K
Boundary Conditions: Lossless Lines01:21

Boundary Conditions: Lossless Lines

Consider a single-phase, two-wire, lossless transmission line terminated by an impedance at the receiving end and a source with Thevenin voltage and impedance at the sending end. The line, with length, has a surge impedance and wave velocity determined by the line's inductance and capacitance.
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...
437
Electrostatic Boundary Conditions in Dielectrics01:27

Electrostatic Boundary Conditions in Dielectrics

When an electric field passes from one homogeneous medium to another, crossing the boundary between the two mediums imparts a discontinuity in the electric field. This results in electrostatic boundary conditions that depend on the type of mediums the field propagates through.
Consider a case where both the mediums across a boundary are two different dielectric materials. Recall that the electric field and electric displacement are proportional and related through the material's permittivity....
1.9K