Related Experiment Video
Updated: Feb 7, 2026

A Structured Approach to Extubation in Mechanically Ventilated Rats
Published on: July 18, 2025
Prolonged mechanical ventilation worsens sepsis-induced diaphragmatic dysfunction in the rat
Matthieu Le Dinh1, Serge Carreira2,3, Julie Obert4
1Sorbonnes Universités UPMC Univ Paris 06, UMRS INSERM 1158, Paris, France.
Background:
Short-term mechanical ventilation (MV) protects against sepsis-induced diaphragmatic dysfunction. Prolonged MV induces diaphragmatic dysfunction in non-septic animals, but few reports describe the effects of prolonged MV in sepsis. We hypothesized that prolonged MV is not protective but worsens the diaphragmatic dysfunction induced by a mild sepsis, because MV and sepsis share key signaling mechanisms, such as cytokine upregulation.
Method:
We studied the impact of prolonged MV (12 h) in four groups (n = 8) of male Wistar rats: 1) endotoxemia induced by intraperitoneal injection of Escherichia coli lipopolysaccharide, 2) MV without endotoxemia, 3) combination of endotoxemia and MV and 4) sham control. Diaphragm mechanical performance, pro-inflammatory cytokine concentrations (Tumor Necrosis Factor-α, Interleukin-1β, Interleukin-6) in plasma were measured.
Results:
Prolonged MV and sepsis independtly reduced maximum diaphragm force (-27%, P = 0.003; -37%, P<0.001; respectively). MV and sepsis acted additively to further decrease diaphragm force (-62%, P<0.001). Similar results were observed for diaphragm kinetics (maximum lengthening velocity -47%, P<0.001). Sepsis and MV reduced diaphragm cross sectional area of type I and IIx fibers, which was further increased by the combination of sepsis and MV (all P<0.05). Sepsis and MV were individually associated with the presence of a robust perimysial inflammatory infiltrate, which was more marked when sepsis and MV were both present (all P<0.05). Sepsis and, to a lesser extent, MV increased proinflammatory cytokine production in plasma and diaphragm (all P<0.05); proinflammatory cytokine expression in plasma was increased further by the combination of sepsis and MV (all P<0.05). Maximum diaphragm force correlated negatively with plasma and diaphragmatic cytokine production (all p<0.05).
Conclusions:
Prolonged (12 h) MV exacerbated sepsis-induced decrease in diaphragm performance. Systemic and diaphragmatic overproduction of pro-inflammatory cytokines may contribute to diaphragm weakness.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation I: Indication and Settings
Mechanisms of Retrovirus-induced Cancers
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...

