Introduction:
Left atrial appendage occlusion procedure (LAAO) became an alternative method for stroke prevention in atrial fibrillation (AF) patients with contraindication or intolerance for oral anticoagulation therapy. However, LAA anatomy is complex with several different types of LAA morphology. Therefore matching the correct size of a delivery device to LAA morphology is difficult. In such circumstances, the 3D-printed model of LAA closure may be useful for preoperative planning which increases the efficacy of LAAO procedure.
Material And Methods:
We report as a first 2 cases of LAA occlusion procedure using 2 different systems: thoracoscopic AtriClip and the LARIAT device in which a 3D printed LAA model was used in preoperative planning.
Results:
In the first patient, preoperative measurements of 3D LAA model were performed using a dedicated selection guide for AtriClip device were comparable with the intraoperative examination. Left atrial appendage was closed epicardial using 40 mm size AtriClip. In second patients, LAA closure was performed completely percutaneously using LARIAT device. For better visualization of LAA shape on fluoroscopy and TEE examination, intraoperatively sterilized 3D LAA model was used during the procedure. In both cases, intraoperative TEE examination confirmed complete LAA closure with no leak.
Conclusions:
Left atrial appendage 3D model is a useful tool in preoperative planning of a left atrial appendage occlusion using epicardial approaches with thoracoscopic or percutaneous access using LARIAT device. The quality of low-cost 3D printed LAA model is sufficient in planning minimally invasive procedure.
Related Concept Videos
Initiation of Translation
First, the initiator tRNA must be selected from the pool of elongator tRNAs by eukaryotic initiation factor 2 (eIF2). The initiator tRNA (Met-tRNAi) has conserved sequence elements including modified bases at...
Initiation of Translation
Clinical Applications of Epidermal Stem Cells
Surface Appendages of Archaea
Local Anesthetics: Clinical Application as Spinal Anesthesia
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...