Ultrasound-guided pleural cutting needle biopsy: accuracy and factors influencing diagnostic yield
Yuxin Zhang1, Jiaxin Tang2, Xinghua Zhou1
1Department of Ultrasound, First Affiliated Hospital of Guangzhou Medical University, Guangzhou 510120, China.
Background:
The aim of this study was to retrospectively investigate the diagnostic accuracy of ultrasound-guided pleural cutting needle biopsy (US-guided PCNB) and the potential factors influencing diagnostic yield.
Methods:
From July 2014 to June 2016, a total of 147 percutaneous US-guided PCNBs in 144 patients were retrospectively reviewed. The final diagnosis was confirmed by histopathological analysis and follow-up. We calculated diagnostic accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) and divided all cases into group of correct diagnoses (true-positive and true-negative cases) and group of incorrect diagnoses (false-positive, false-negative, and inconclusive cases). Univariate and multivariate logistic regression analyses were performed to analyze the differences of influencing factors (patient, pleura, and biopsy-associated factors) in the between the two groups.
Results:
Seven patients were excluded because of loss to follow-up. A total of 140 cases were ultimately included (105 males and 35 females). There were 105 cases in the correct diagnosis group, and 35 cases in the incorrect diagnosis group. The overall accuracy of US-PCNB was 75.0% and the sensitivity, specificity, PPV, NPV in malignant diagnosis were 58.1%, 99.0%, 96.2%, and 84.2%, respectively. On univariate analysis, variables affecting diagnostic accuracy of US-PCNB were the pleural thickness (<3 mm in thickness 61.0%, ≥3 mm in thickness 85.2%; P=0.001), morphology (non-nodular pleura 71.4%, nodular pleura 95.2%; P=0.026), and needle size (18 G 69.1%, 16 G 87.0%; P=0.022). Finally multivariate logistic regression demonstrated that pleural thickness [odds ratio (OR): 0.278, P=0.003] and needle size (OR: 0.291, P=0.018) independently predicted diagnostic accuracy.
Conclusions:
Pleural thickness and the size of the biopsy needle were significantly correlated with the diagnostic yield.
More Related Videos
05:18Author Spotlight: Ultrasound-Guided Needle Release Combined with Corticosteroid Injection for the Treatment of Supinator Syndrome
Published on: May 26, 2023
08:08Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
Published on: March 6, 2019
Related Concept Videos
Bioavailability: Influencing Factors
Improving Translational Accuracy
Factors Influencing Microbial Growth: pH
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Factors Influencing Attraction I: Proximity
Factors Influencing Attraction VI: Personality Traits