Effect of pneumoperitoneum and steep reverse-Trendelenburg position on mean systemic filling pressure, venous return, and microcirculation during esophagectomy
Related Experiment Video
Updated: Feb 7, 2026

Measurement of the Hepatic Venous Pressure Gradient and Transjugular Liver Biopsy
Published on: June 18, 2020
Huaiwu He1, Guillem Gruartmoner2, Yilmaz Ince3
1Department of Critical Care Medicine, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Science, Beijing 100000, China.
Background:
Keeping adequate tissue perfusion during high-risk abdominal surgery is of utmost importance to decrease postoperative complications. The objective was to investigate the alteration in mean systemic filling pressure (MSFP), venous return (VR) and sublingual microcirculation during pneumoperitoneum and steep reverse-Trendelenburg position during thoracolaparoscopic esophagectomy.
Methods:
This is a single-center prospective observational study in operating room at a university hospital. Eleven consecutive patients undergoing minimally invasive esophagectomy. Intraoperative hemodynamic and sublingual microcirculatory variables were simultaneously measured within 5 minutes at the following time points: T1, baseline supine position before the start of surgery; T2, pneumoperitoneum in supine position; T3, steep reverse-Trendelenburg position after the pneumoperitoneum. The cardiac output (CO) was obtained with continuous pulse contour waveform-derived measurements, and the MSFP was estimated with the analogue method.
Results:
The pneumoperitoneum and reverse-Trendelenburg caused an increase in stroke volume variation (SVV), MSFP and central venous pressure (CVP), and a decrease in the microcirculatory perfusion index (MFI, <0.05). However, changes in CO, pressure gradient of VR, resistance of VR and blood pressure were not consistent and did not differ significantly across timepoints. Moreover, MFI is significantly related to CVP and MSFP but not to CO and blood pressure (BP). Measurements with MFI ≤2 have a higher CVP and MSFP compared to those with MFI >2. Using a CVP ≥23 mmHg to detect MFI ≤2 results in a sensitivity of 61.54% and a specificity of 100%.
Conclusions:
A high CVP is related to poor microcirculatory flow perfusion even if the macrocirculation has been maintained during pneumoperitoneum.
Related Concept Videos
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system...
Root Loci for Positive-Feedback Systems
The construction rules for the root locus in positive feedback systems are similar to those in...
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Venous Thrombosis I: Introduction
Position-effect Variegation
Osmosis and Osmotic Pressure of Solutions