Molecular Dynamics and Umbrella Sampling Simulations Elucidate Differences in Troponin C Isoform and Mutant

Jacob D Bowman1, Steffen Lindert1

  • 1Department of Chemistry and Biochemistry , Ohio State University , Columbus , Ohio 43210 , United States.

Related Concept Videos

Molecular Chaperones and Protein Folding03:00

Molecular Chaperones and Protein Folding

The native conformation of a protein is formed by interactions between the side chains of its constituent amino acids. When the amino acids cannot form these interactions, the protein cannot fold by itself and needs chaperones. Notably, chaperones do not relay any additional information required for the folding of polypeptides; the native conformation of a protein is determined solely by its amino acid sequence. Chaperones catalyze protein folding without being a part of the folded protein.
The...
19.8K
Molecular Models02:00

Molecular Models

Physical models representing molecular architectures of chemical compounds play essential roles in understanding chemistry. The use of molecular models makes it easier to visualize the structures and shapes of atoms and molecules.
43.8K
Long-patch Base Excision Repair01:02

Long-patch Base Excision Repair

Since the discovery of the two BER pathways, there has been a debate about how a cell chooses one pathway over the other and the factors determining this selection. Numerous in vitro experiments have pointed out multiple determinants for the sub-pathway selection. These are:
8.0K
Dynamic Equilibrium02:20

Dynamic Equilibrium

A reversible chemical reaction represents a chemical process that proceeds in both forward (left to right) and reverse (right to left) directions. When the rates of the forward and reverse reactions are equal, the concentrations of the reactant and product species remain constant over time and the system is at equilibrium. A special double arrow is used to emphasize the reversible nature of the reaction. The relative concentrations of reactants and products in equilibrium systems vary greatly;...
63.0K
Electric Potential and Potential Difference01:16

Electric Potential and Potential Difference

Suppose a positive test charge moves away from a positive static charge, then the Coulomb force does positive work, and its electric potential energy decreases. The potential energy per unit charge is defined as the electric potential. The electric potential is independent of the test charge.
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
5.7K
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
8.4K