Background:
This study assessed the safety and performance of the Omnipod® personalized model predictive control (MPC) algorithm using an investigational device in adults with type 1 diabetes in response to overestimated and missed meal boluses and extended boluses for high-fat meals.
Materials And Methods:
A supervised 54-h hybrid closed-loop (HCL) study was conducted in a hotel setting after a 7-day outpatient open-loop run-in phase. Adults aged 18-65 years with type 1 diabetes and HbA1c 6.0%-10.0% were eligible. Primary endpoints were percentage time in hypoglycemia <70 mg/dL and hyperglycemia ≥250 mg/dL. Glycemic responses for 4 h to a 130% overestimated bolus and a missed meal bolus were compared with a 100% bolus for identical meals, respectively. The 12-h postprandial responses to a high-fat meal were compared using either a standard or extended bolus.
Results:
Twelve subjects participated in the study, with (mean ± standard deviation): age 35.4 ± 14.1 years, diabetes duration 16.5 ± 9.3 years, HbA1c 7.7 ± 0.9%, and total daily dose 0.58 ± 0.19 U/kg. Outcomes for the 54-h HCL period were mean glucose 153 ± 15 mg/dL, percentage time <70 mg/dL [median (interquartile range)]: 0.0% (0.0-1.2%), 70-180 mg/dL: 76.1% ± 8.0%, and ≥250 mg/dL: 4.5% ± 3.6%. After both the 100% and 130% boluses, postprandial percentage time <70 mg/dL was 0.0% (0.0-0.0%) (P = 0.50). After the 100% and missed boluses, postprandial percentage time ≥250 mg/dL was 0.2% ± 0.6% and 10.3% ± 16.5%, respectively (P = 0.06). Postprandial percentages time ≥250 mg/dL and <70 mg/dL were similar with standard or extended boluses for a high-fat meal.
Conclusions:
The Omnipod personalized MPC algorithm performed well and was safe during day and night use in response to overestimated, missed, and extended meal boluses in adults with type 1 diabetes.
More Related Videos
Related Concept Videos
Predicting Products: SN1 vs. SN2
With increased substitution on the alkyl halide,...
Diabetes Mellitus: Type 2 and Gestational
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
High-Performance Liquid Chromatography: Types of Detectors